KitchenAid PRO LINE KHEV01RSS0 Use & Care Manual page 8

Pro line front-loading electric dryer
Hide thumbs Also See for PRO LINE KHEV01RSS0:
Table of Contents

Advertisement

_
___
_:_u _'_
'! _ '
Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect
power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical
connections.
Failure to de so can result in death, fire, or
electrical
shock.
Direct Wire
Fire Hazard
Use 10 gauge solid copper
wire.
Use a UL listed strain
relief.
Disconnect
power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected
to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical
shock.
f.
Disconnect
power.
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
2. Position the dryer so that the rear of the dryer is within 4 ft
(1.2 m) of its final location.
3. Remove the hold-down
screws and terminal block cover.
D
/
/
!
4.
Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a %" (1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing toward you and the
other is pointing away from you, and hold in place.
Tighten strain relief screws just enough to hold the two
clamp sections together.
A
...................................................
B
.......................... C
A. Strain relief tab pointing
up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing
down
A. Neutral ground wire
B. External ground conductor screw
C. Center, silver-colored
terminal block screw
D. Terminal block cover and hold-down
screws

Advertisement