Electrical Requirements - KitchenAid KHTU705RSS1 Installation Instructions And Use & Care Manual

30" (76.2 cm) and 36" (91.4 cm) range hood with interchangable style front
Hide thumbs Also See for KHTU705RSS1:
Table of Contents

Advertisement

Available languages

Available languages

ForBestPerformance:
[] Donotinstall 2elbows t ogether.
[] Usenomore than three 90 °elbows.
[] Ifanelbow isused, i nstall itasfaraway a spossible from the
hood's v ent m otor e xhaust opening.
[] Make sure there isaminimum o f24"(61cm) o fstraight vent
between theelbows i fmore than oneelbow isused.
[] The length o fvent s ystem andnumber ofelbows s hould b e
kept t oaminimum t oprovide e fficient performance.
Cold Weather lnetalmatione
Anadditional backdraft damper should b einstalled tominimize
backward coldairflowand a nonmetallic
thermal break i nstalled
tominimize conduction ofoutside t emperatures
aspart o fthe
vent s ystem. The damper should b eonthecoldairside ofthe
thermal break.
Makeup A ir
Local building codes m ay require theuseofmakeup a irsystems
when using v entilation systems greater thanspecified CFM ofair
movement.
The specified CFM varies f rom locale tolocale.
Consult your H VAC professional
forspecific r equirements
inyour
area,
Venting
methods
This range hood is factory set for vented installations. Vent
system can terminate through either the roof or wall. A
6" (15.2 cm) round vent system must be used. The vent system
length should not exceed 35 ft (10.7 m).
Option 1 -
Option 2
Roof venting
Wall venting
Option 3 -
Rear exhaust
wall venting
A
.....
A. 6" (15.2 cn'_)round venting
B. Roof cap
C. Waftcap
The exhaust collar can also be directed to vent out the rear of the
hood.
Calculating
Vent System
Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent piece
6" (15.2 cm) round
45 ° elbow
2.5 ft (0.8 m)
_
....
i
90 ° elbow
5.0 ft (1.5 m)
E×ample
vent system
90° elbow
_-
6 ft, (1.8 m) _'_
wall cap
\
/
2fL
(0_6 rn)
Maximum
_ength
= 35 ft (10.7 m)
1-90 ° elbow
= 5 ft (1.5 m)
8 ft (2.4 m) straight
= 8 ft (2.4 m)
1 - wall cap
= 0 ft (0 m)
System length
= 13 ft (3.9 m)
NOTE: Flexible vent is not recommended.
Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
IMPORTANT.- Observe all governing codes and ordinances. Save
installation instructions for electrical inspector's use.
it is the customer's responsibility to contact a qualified electrical
installer, and to assure that the electrical installation is adequate
and in conformance with National Electrical Code, ANSI/NFPA 70
(latest edition), or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local
codes and ordinances.
if codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch
Park, Quincy, MA 02269
CSA international
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120-volt, 60-Hz, AC-only, 15 amp, fused electrical circuit is
required.
Do not ground to a gas pipe.