KitchenAid KXD4630YSS0 Use & Care Manual page 19

30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system
Table of Contents

Advertisement

Available languages

Available languages

Complete
Preparation
1. Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the floor, ceiling or
wall, do not damage electrical wiring or other hidden utilities.
2. Determine the location where the 1/2"(1.3 cm) wiring conduit
will be routed through the floor, ceiling or wall between the in-
line blower and the downdraft vent.
3. Drill a 1V4" (3.2 cm) hole at this location.
4. Locate the electrical terminal boxes in the in-line blower
housing and downdraft vent. Remove the terminal box covers
and set the covers and screws aside.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical
shock.
/
A
A. Electrical terminal box
B. Electrical knockout
5. Remove the electrical knockout from the in-line blower
housing and downdraft vent to prepare for the installation of
the UL listed or CSA approved 1/2"(1.3 cm) wiring conduit and
conduit connector.
6. With the downdraft vent mounted, run the 1/2"(1.3 cm) wiring
conduit between the in-line blower motor housing and the
downdraft vent. Pull enough 1/2"(1.3 cm) wiring conduit to
allow for easy connection to the terminal boxes in the in-line
blower housing and downdraft vent.
7. Run the six 18 AWG wires through the 1/2"(1.3 cm) wiring
conduit and conduit connectors
and into the terminal boxes
on the in-line blower housing and downdraft
vent. Leave
enough wire length in each terminal box to make the wiring
connections.
8. Install the conduit connectors and conduit to the in-line
blower housing and downdraft
vent electrical terminal boxes.
9. Connect the vent system to the downdraft vent and in-line
blower system and seal all joints with clamps.
Electrical
Connection
Inside In-line Blower System
1. Disconnect
power.
2. Connect the wires from the wiring conduit to the wires from
the motor electrical plug cable inside the in-line blower
housing terminal box.
B
C
A
A. UL fisted or CSA approved
½" (1.3 cm) wiring conduit
B. UL fisted wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or yellow/green)
and green/yellow
wires
I. Motor electrical plug cable
3. Use UL listed wire connectors
and connect the black wires
(C) together.
4. Use UL listed wire connectors
and connect the white wires
(D) together.
5. Use UL listed wire connectors
and connect the red wires (E)
together.
6. Use UL listed wire connectors
and connect the blue wires (F)
together.
7. Use UL listed wire connectors and connect the gray wires (G)
together.
19