KitchenAid KXD4630YSS0 Use & Care Manual page 14

30" (76.2 cm) and 36" (91.4 cm) retractable (pop-up) downdraft vent system
Table of Contents

Advertisement

Available languages

Available languages

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect
power.
2. Feed the power supply cable through the conduit connector
and into the terminal box.
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal
box.
Failure to do so can result in death or electrical
shock.
3. Connect the green (or green/yellow)
ground wire to the green
or yellow/green
ground wire using UL listed wire connectors.
Tighten the screw on the conduit connector.
4. Connect the 2 white wires together using UL listed wire
connectors.
F
C
5. Connect the 2 black wires together using UL listed wire
connectors.
6. Replace the terminal box cover and secure with screw.
7. Reconnect power.
1=
.....
I,_)I. Ol _.II]011
Push and hold the button on the top of the downdraft vent for
a few seconds. The retractable section of the downdraft vent
will rise, and the blower will start. Position the top trim over
the retractable section and snap trim into place.
Trim kits for matching your cooktop color are available from
your dealer.
For information
on ordering, see the "Assistance or Service"
section.
B
E
2=
3.
A. Top trim
B. ON/OFF button
C. Blower control sfider
D. End cap
E. Filters
Slide the control slider on the side of vent to check the
operation and speed of the blower.
If the blower does not operate:
Check that filter or filters are pressed in as far as they will
go.
Check that the circuit breaker has not tripped or a
household fuse blown.
4. Connect vent system to blower. Vent system must end with a
wall or roof cap. Use clamps or duct tape to seal all joints.
5. Install cooktop according to manufacturer's
instructions.
Check that rear of cooktop overlaps edge of retractable
downdraft vent by 3/8"(9.5 mm). See "Countertop
Cutout
Dimensions"
in the "Location
Requirements" section.
NOTE: To get the most efficient use from your new retractable
downdraft vent, read the "Vent System Use" section.
A. Green or green and yellow ground wire
B. White wires
C. UL listed wire connectors
D. Black wires
E. UL listed or CSA approved conduit connector
F Downdraft
vent wiring
14