Venting Requirements - Jenn-Air JXT6036ADR0 Use & Care Manual

30" and 36" (76.2 cm and 91.4 cm) wall-mount canopy range hood installation instructions
Hide thumbs Also See for JXT6036ADR0:
Table of Contents

Advertisement

Non-Vented (recirculating) Installations
1=
Connect the deflector to the vent cover bracket using 4 - 3.5
x 9.5 sheet
metal screws
provided.
A. Vent cover bracket
B. C3.5 x 9.5 mm sheet metal screws
Complete Preparation
1. Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
"Venting Requirements" section.
2. Determine the required height for the home power supply
cable and drill a 11¼"(3.2 cm) hole at this location.
3. Run wire through the home power supply cable according to
the National Electrical Code or CSA Standards and local
codes and ordinances. There must be enough 1/2"conduit
and wires from the fused disconnect
(or circuit breaker) box
to make the connection
in the hood's electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
1=
Using 2 or more people, hang range hood on 2 mounting
hooks through the rectangular cutouts on back of hood.
A. Mounting hooks
B. 5 x 35 mm mounting screws
C. Leveling screws
D. Centerline on wall
2. Level the hood with leveling screws in mounting hooks or
rectangular cutouts, using a level across bottom of hood.
3. Secure hood with 4 screws through remaining 4 holes in
hood.
1=
Install transition on top of range hood (if removed for
shipping) with 4 - 3.5 x 9.5 mm sheet metal screws.
B
A. Vent transition
B. 3.5 x 9.5 mm screw
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jxt6030adr0

Table of Contents