Electrical Requirements - Fedders 23-23-0321N-002 Installation & Operation Manual

Room air conditioners for double-hung windows 5,000-18,000 btu's
Table of Contents

Advertisement

Available languages

Available languages

1
Electrical
Shock
Hazard
. Plug unit only into grounded electrical
outlet.
• Do not use an extension
cord or plug adaptor with
this unit.
3.
Do not operate unit with front removed.
Failure to follow the above precautions
could result in electrical
shock, fire or personal injury,
If the
air conditioner
has a serial
plate
rating
of 115
volts
and
up
to and
including
7.5
amps
the
unit
may
be on a fuse
or circuit
breaker
with
other
devices.
However,
the ma;dmum
amps
of all devices
on that fuse
or circuit
breaker
can
not exceed
the amps
of the hlse
or circuit
breaker.
If tile
air conditioner
has a serial
plate
rating
of
115 volts
and
oreater
than
7.5
anlps
it must
have
its own
fuse
or cir-
cuit
_reaker,
and
no
other
device
or
unit
should
be operated
on that
fuse
or circuit
breaker.
If tile
air conditioner
has a serial
plate
rating
of 2_0
vohs
it inust
have
its own
fuse
or circuit
breaker,
and
no
other
device
or unit
should
be operated
on
that
fuse
or circuit
breaker.
The
location
of tile
serial
plate
that
applies
to this
inodel
can
be found
on tile
back
page of this
manual.
Notice
Do not or_erate this air conditioner
without
proper time
delay circuit protection.
Refer to serial plate for proper
power supply requirenlents.
RECOMMENDED CIRCUI T WIRE SIZES
(As installed per building code)
PROTECTOR SIZE
WIRE GAUGE
15 AMP
#14 MINIMUM
20 AMP
#12 MINIMUM
30 AMP
#10 MINIMUM
@©©@
115V
230V
230V
230V
15,4
15A
20,4
30,4
1. ELECTRICAL REQUIREMENTS
Grounded
Single outlet
three-prong
grounding
wall
receptacle
wall
receptacle
Three-prong
grounding
plug
Important
Grounding
Requirements
1. Air conditioner
has a three-prong grounding
plug on power supply cord, which must be
plugged into properly grounded three-prong
wall receptacle for your protection against
possible shock hazard. For models up to and
including
7.5 amperes use grounding type
wall receptacle to match cord plug (Fig. 1).
2,
For
models
above
7.5
amperes
use
single
outlet
grounding type wall receptacle
to
match
cord
plug (Fig. 2).
Caution: We recommend that a qualified electrician
insta# unit in accordance with the National Electrical
Code and local codes and ordinances.
Caution: Use copper conductors only.
Product
Damage:
Do not cut, alter or remove any of the expanded
polystyrene
(white foam) inside this air conditioner.
For
Your
Safety:
Do
not
store
or use
gasoline
or other
flamlnable
vapors
and
lic uids
in the
vicinity
of this
or any
other
appliance.
Tie
fumes
can
create
a fire
lazar(
or exp
osion.
Tools
Needed
Screwdrivers
/_t
Ruler
"--_-_g
.7 /
or tape
measure
I
Level
_
I
Pencil
4r__,
Window
Requirements
1.
Air
conditioner
is factory
prepared
for
instal-
lation
in standard
double
hung window
(air
conditioner
cannot
be
installed
in other
types
of windows
without
modification,
consult
with
a qualified
installation
serviceman).
2,
Install
the
air
conditioner
in a window
where
there
will
be
enough
clearance
around
the
cabinet
to
allow
ample
circulation
of air
through
the
unit.
Caution: Do not block air circulation
to outside
louvers of cabinet.
3.
All supporting
parts should
be secured
to
firm wood,
masonry
or metal,