Download Print this page

Jenn-Air JGD8430ADB Use & Care Manual page 5

Gas on glass downdraft cooktop

Advertisement

Available languages

Available languages

IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT
NOTICE REGARDING
PET BIRDS:
Never keep pet birds in the kitchen or in rooms where
the fumes from the kitchen could reach. Birds have a
very sensitive respiratory
system. Fumes released during
an oven self-cleaning
cycle may be harmful or fatal to
birds. Fumes released due to overheated
cooking oil,
fat, margarine
and overheated
non-stick
cookware
may
be equally harmful.
Electrical Connection
Appliances
which
require electrical
power are equipped
with a three-prong
grounding
plug which must be
plugged directly into a properly
grounded three-hole
120 volt
electrical outlet.
Always disconnect power to appliance before servicing.
The three-prong
grounding
plug offers protection
against shock hazards. DO NOT CUT OR REMOVE
THE THIRD
GROUNDING
PRONG FROM THE
POWER CORD PLUG.
If an ungrounded,
two-hole
or other type electrical
outlet is encountered,
it is the personal
responsibility
of the appliance
owner to have the outlet replaced
with a properly grounded
three-hole
electrical
outlet.
Ducting Information
Jenn-Air's ventilation
system is designed to capture
both cooking fumes and smoke from the cooktop
surface. If the system does not, these are some ducting
installation
situations to check:
• 6" diameter round or 3 1/4" x 10" rectangular
ducting
should be used for duct lengths 10'-60'.
I Note:
Use 5" diameter round ducting if the duct
length is 10' or less.
• No more than three 90 ° elbows should be used.
Distance between elbows should be at least 18".
• Recommended
Jenn-Air wall cap MUSTbe
used.
Make sure damper moves freely when ventilation
system is operating.
• There should be a minimum
clearance of 6" for
cooktop installed near a side wall.
• There should be a minimum
clearance of 12" between
the bottom of the wall cap and the ground.
If there is not an obvious improper
installation, there
may be a concealed problem such as a pinched joint,
obstruction
in the pipe, etc. Installation
is the responsi-
bility of the installer and questions
should be addressed
first by the installer. The installer should very carefully
check the ducting installation
instructions.
• Use the Flow Tester Card provided with
your appliance to check the air flow.
FLOW
TESTER
t
Save These Instructions for Future Reference