Lubrication
The
cleaner
is
equipped
with
bearings
that
contain
sufficient
lubrication
for
the
life
of
the
cleaner,
The
addition
of
lubri-
cant
could
cause
damage,
Therefore,
do not add lubricant to any bearings.
I d"_ ,'J I;r'_
[_]_|PTI_
Thermal
protector
An
internal
thermal
protector
has
been
designed
into
your
cleaner
to
protect
it
from
overheating,
When
the thermal
protector
activates,
the suction
motor
will
stop
running,
however
the agitators
will
continue
to
run.
If
this
happens,
pro_;eed
as
follows:
1.
Turn
the
cleaner
OFF
and
discon-
nect
it from
the
electrical
outlet.
2.
Check
dirt
cup
pre-filter,
HERA
cartridge
filter
and
final
filter
for
dirt
accumulation.
3.
Refer
to
"Clearing
blockages"
section.
4. When
the motor cools,
the
thermal
protector
automatically
resets
and
cleaning
may
continue.
If the
thermal
protector
continues
to
activate
after
following
the
above
steps,
your
cleaner
may
need
servicing
(see
"Service"
section).
I;Tt;I .'3 P-I_I_] Pd_"R31 h'l_'_l_l eTtl_ _
_r_
Ipl[;] i i )if]
[;,_. | l I i i [I i 1-_1_ _.-I_TLI]
lil
I| [_ :!
I
Hoover
Cleaning
Perform
a n c e
This
Hoover
Cleaning
Performance
Sys-
tem
is
for
comparing
the
relative
pro-
gressive
performance
of
Hoover
uprights
0nly
and
not
for
comparison
with
any
other
brands.
The
majority
of
this
rating
is
based
upon
the
American
Society
for
Testing
and
Materials
(ASTM)
Carpet
Cleaning
Effectiveness
Test
(ASTM
Test
F608).
Other
performance
factors
include
Hose
Power
(ASTM
Test
F558),
Surface
Litter
Cleaning,
Hard
Floor
Cleaning,
Edge
Cleaning,
Cleaning
Width,
and
Air
Filtration.
12
If a minor
problem
occurs,
it usually
can
be
solved
quite
easily
when
the
cause
is
found
by
using
the
check
list
below.
Possible
cause
Possible
solution
• Not firmly
plugged
in
• Plug
unit
in
firmly
• No voltage
in wall
plug
• Check
fuse
or
breaker
• Blown
fuse
or tripped
breaker
• Replace
fuse
or
reset
breaker
• Thermal
protector
activated
• Allow
cleaner
to
cool
(this
will
reset
the
thermal p_otector) (see pg 12)
Possible
cause
Possible
solution
• Brush
roll switch
in OFF position.
• Turn
brush
roll
switch
ON
• Circuit
breaker
tripped.
• Reset
circuit
breaker
as
described
in
Fig.
2-9
• Agitators
are obstructed.
• Clear
obstruction
Possible
cause
Possible
solution
• Thermal
protector
activated
• Allow
cleaner
to
cool
(this
will
reset
the
thermal
protector)
(see
pg.
12).
• Circuit
breaker
tripped
• Reset
circuit
breaker
as
described
in
Fig.
2-9.
• Agitator
brush rolls worn
• Replace
[)rush
rolls
• Dirt cup full
• Empty
dirt
cup
• Incorrect
carpet
height
setting
Move
nozzle
control
knob
to
lower
setting
• Blockage
in air flow
passage
• Clear
blockage
• HEPA
cartridge
filter
clogged
• Clean
HERA
cartridge
filter
by
either
tapping
the
side
of
the
dirt
cup
or
removing
the
cartridge
filter
as
de-
scribed
in
the
"Filter
assembly"
section.
• Pre-filter
clogged
• Clean
pre-filter
as
described
in
"Filter
assembly"
section.
• Dirt cup
not properly
installed
• Position
dirt
cup
properly
(Fig.
3-5).
• Dirt cup
lid not positioned
properly
or missing
• Ensure
that
dirt
cup
lid
is
properly
positioned.
• Filter
assembly
not assembled
properly
Ensure
that
filter
assembly
is
positioned
properly
(Figs.
3-9 to 3-11).
Possible
cause
Possible
solution
• Incorrect
carpet
height
setting
• Move
nozzle
control
knob
to
a
higher
setting
Possible
cause
Possible
solution
• Blockage
in hose
• Clear
blockage.
Possible
cause
Possible
solution
• Filter
assembly
not installed
properly
Remove
filter
assembly
from
dirt
cup
and
ensure
that
HERA
cartridge
filter
is
properly
attached
to
pre-filter
screen
and
that
entire
filter
assembly
is
properly
repositioned
inside
dirt
cup.
(Figs.
3-6 through 3-11 ).
Note:
Heavy
debris
may
settle
to
the
bottom
of
the
dirt
cup
and
prevent
the
dirt
from
spinning
without
affecting
cleaning
performance.
The
cleaner
can
continue
to
be
used
even
if the
dirt
is
not
spinning
inside
the
dirt
cup.
However,
if the
dirt
does
stop
spinning
AND
there
is
a noticeable
decrease
of
performance,
check
the
items
under
"Cleaner
won't
pick
up'.
Possible
cause
Possible
solution
• Too
much
pressure
being
applied
to
tool
Continue
using
tool
applying
light
pressure.
• Blockage
in turbine
channel
Remove
blockage.
• Broken or worn belt
• Replace
belt
• Low cleaner
suction
• Check
items
under
"Cleaner
won't
pick
up".

Advertisement

loading