Lubrication; Maintenance Authorized Service; Replacing Agitator Brush Roll; Replacing Edge Groomers - Hoover WindTunnel U5471-900 Owner's Manual

Uses hepa filtration type "y" filter bags
Hide thumbs Also See for WindTunnel U5471-900:
Table of Contents

Advertisement

Replacing
bottom
plate
Re£0siti,0n b,0tt0m plate and 4
Phillips nead screws, lighten
screws securely.
The
edge
groomers
When
to replace
The edge groomers, located on both
sides of the nozzle, should be
replaced when they appear worn.
What
to buy
When purchasing edge groomers,
ask for HOOVER part No.
39511004.
How
to replace
Disconnect cleaner from electrical
outlet.
Remove bottom plate as described
in "The belt" section (Fig. 3-10).
The
agitator
brush
roll
When
to
replace
When agitator brushes are worn, the
agitator should be replaced.
To check condition of brushes, dis-
connect cleaner from electrical
outlet.
Move edge of a card across bottom
plate while turning agitator.
To
maintain cleaning effectiveness,
replace agitator if brushes do not
touch card.
What
to buy
Your cleaner requires either a 13" or
15" agitator. When purchasing a
new agitator, ask for one of the fol-
lowing:
13" - HOOVER part No. 48414110
15" - HOOVER part No. 48414115
Installing
groomers
Lift off both old edge groomers and
slide new edge groomers into posi-
tion as shown.
How
to replace
Disconnect
cleaner from electrical
outlet.
Remove bottom plate, belt and agi-
tator followingdirections
in "The
belt" sectionbeginning
with Fig. 3-
10.
Discard old agitator.
Continue following the directions in
"The belt" section to reposition belt,
new agitator and bottom plate.
Lubrication
The motor is equipped with bear-
ings that contain sufficient lubrica-
tion for the life of the motor. The
addition of lubricant could cause
damage. Therefore,
do not add
lubricant
to motor bearings.
The
agitator is equipped with two ball
bearings that should be lubricated
periodically
by a Hoover Factory
Service Center or an Authorized
Hoover Warranty Service Dealer
(Depot).
Reposition bottom plate and secure
with 4 Phillips head screws.
Thermal
protector
An internal thermal protector has been
designed into your cleaner to protect
it from overheating.
When the thermal protector acti-
vates, the cleaner will stop running.
If this happens, proceed as follows:
1. Turn the cleaner OFF and discon-
nect it from the electrical outlet.
2. Check secondary and final filters
for dirt accumulation.
3. Refer to "Clearing blockages"
section.
4. When cleaner
is unplugged
and
the motor cools for 30 minutes,
the
thermal protector automatically
resets
and cleaning may continue.
If the thermal protector continues to
activate after following the above
steps, your cleaner may need servic-
ing (see "Service" section).
Service
To obtain approved HOOVER service
and genuine HOOVER parts, locate
the nearest Hoover Factory Service
Center or Authorized
Hoover
Warranty
Service Dealer (Depot)
by:
° checking the Yellow Pages
under "Vacuum Cleaners-House-
hold" OR -
• checking the list of Factory
Service Centers provided with this
cleaner OR -
• checking the Service section of
The Hoover Company on-line at
www.hoover.com
OR -
° calling 1-800-944-9200 for an
automated referral of authorized ser-
vice outlet locations (U.S. only).
Do not send your cleaner to The
Hoover Company in North Canton for
service, this will only result in delay.
If further assistance is needed, con-
tact The Hoover Company
Consumer Response Center, North
Canton, Ohio 44270,
Phone: 1-330-
499-9499.
In Canada, contact Hoover Canada,
Burlington, Ontario L7R 4A8,
Phone:
1-800-263-6376.
Always identify your cleaner by the
complete model number when
requesting information or ordering
parts. (The model number appears
on the bottom of the cleaner.)
11