INSTALLING THE DOWNDRAFT VENT SYSTEM
POWER SUPPLY
This downdraft
vent
must
be supplied
with
120V, 60Hz., and connected
to an individual,
properly
grounded
branch
circuit,
protected
by a 15 or 20 ampere
circuit
breaker
or time
delay
fuse.
Gas Cooktops
If this vent
is installed
in combination
with
a
gas cooktop,
it may operate
from
the same
duplex
outlet.
Electric
Cooktops
If this vent
is installed
in combination
with
an
electric
cooktop,
the vent
must
operate
from
a separate
120V outlet.
A properly
grounded
3-prong
receptacle
should
be located
within
reach
of the vents'
2 foot
power
cord.
• Locate
the receptacle
inside
the cabinet
on
the right
side wall.
The receptacle
cannot
be placed
on the back of the cabinet
wall
where
it may interfere
with
the downdraft
plenum.
See illustration.
Do not leave gas or electrical
connections
within
shaded area.
outlet
12" above
cabinet floor
281½" for 30" model,'
NOTE:
Do not use an extension
cord
or
adapter
plug with
this appliance.
Follow
National
electrical
codes
or prevailing
local
codes
and ordinances.