Emerson LA FAYETTE CF820ORB00 Owner's Manual page 11

37.0 lbs. oil rubbed bronze/pewter
Table of Contents

Advertisement

Setting Operating
Frequency of Wall Control
and Receiver
Your wall control and receiver have code switches
which must be set in one of 16 possible code
combinations. The four levers (numbered 1, 2, 3, and
4) on the switches are factory-set in the ON (up)
position. Change the switch settings as follows:
1. Slide the four switch levers in the wall control to
your choice of ON (up) or down positions. Use a
ball-point pen or small screwdriver and slide the
levers firmly up or down.
2. In the receiver, slide the four switch levers to the
same positions as set in the wall control. Make
sure the levers on both switches are in the same
positions, otherwise the fan will not operate.
CODE
SWITCH
ON
1
2
3
4
RECEIVER SWITCH
LEVERS
SW116 WALL
CONTROL
Figure 24
(Figure 24)
SW105 RECEIVER
ON
1
2
3
4
WALL CONTROL
LEVERS
HI
HI
LIG HT
MED
MED
LOW
LOW
REV
REV
FAN OFF
CODE
SWITCH
Installation
of Wall Control
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse or circuit breaker box.
The SW116 wall control transmits the command
signals via radio waves to the SW105 receiver
installed in the ceiling fan ceiling cover. The
SW105 receiver is required for the SW116 wall
control to function. Power for the SW116 wall
control comes from the 12V battery, located in the
wall control.
Replacement 12V batteries recommended are
Duracell MN21, Eveready A23, and GP23A.
1. Install the 12V battery (supplied) into the wall
control (Figure 25).
2. The SW116 wall control is supplied with a white,
ivory or almond color cover. Choose the style that
best suits your needs and snap the cover onto the
wall control (Figure 25).
U/ L
D/ L
WALL
CONTROL
COVER
Figure 25
3. Install the wall control onto the outlet box using the
supplied screws (Figure 26).
4. Install decorator wallplate (not included) using the
two screws provided with the wall plate. Leave wall
control in "OFF" mode until fan installation is
completed (Figure 26).
DECORATIVE WALL PLATE
(Purchased Separately)
WALL PLATE
SCREW (2)
Figure 26
11
WARNING
HI
HI
LI GH T
ME D
ME D
LO W
LO W
RE V
RE V
FAN OF F
12V BATTERY
SW116 WALL
CONTROL
OUTLET BOX
U/L
HI
LIGH T
MED
D/L
LOW
REV
FAN OFF
SW116 WALL
CONTROL
WALL CONTROL
SCREW (2)
U.L. Model No.: CF820