Craftsman 919.165613 Owner's Manual page 20

Permanently lubricated twin v 2-stage stationary
Hide thumbs Also See for 919.165613:

Advertisement

Available languages

Available languages

Risk of Unsafe
Operation.
Unit cycles
automatically
when
power
is on. When
servicing,
you may be exposed
to
voltage
sources,
compressed
air, or moving
parts.
Before
servicing
unit
unplug
or disconnect
electrical
supply
to the air compressor,
bleed
tank of
pressure,
and allow the air compressor
to cool.
PROBLEM
Excessive
tank
pressure
- safety
valve pops
off.
Air leaks at
fittings.
Air leaks at or
inside
check
valve
CAUSE
CORRECTION
Air leaks at
pressure
switch
release
valve.
Air leaks in air
tank or at air
tank welds.
Pressure
switch
does
not shut off
motor
when
compressor
reaches
"cut-
out" pressure.
Pressure
switch
"cut-out"
too high.
Tube fittings
are not tight
enough.
Check
valve seat damaged.
Defective
pressure
switch
release
valve.
Defective
air tank.
Leaking
seal.
Air leaks
between
head
and valve plate.
Move On/Auto/Off
lever to
the "Off"
position,
if the unit
does
not shut off contact
a
Trained
Service
Technician.
Contact
a Trained
Service
Technician.
Tighten
fittings
where
air
can be heard escaping.
Check
fittings
with soapy
water
solution.
Do Not
Overtighten,
A defective
check
valve
results
in a constant
air leak
at the pressure
release
valve
when there
is pressure
in the
tank and the compressor
is shut off. Replace
check
valve.
Refer the To Replace
or Clean
Check
Valve in
the Service
and Adjustment
section.
Contact
a Trained
Service
Technician.
Air tank must be replaced.
Do not repair the leak.
Risk of
Bursting.
Do not drill into, weld or
otherwise
modif_j
air tank
or it will weaken.
The tank
can rupture
or explode,
Contact
a Trained
Service
Technician.
N004083
20- ENG