Craftsman 919.165613 Owner's Manual page 11

Permanently lubricated twin v 2-stage stationary
Hide thumbs Also See for 919.165613:

Advertisement

Available languages

Available languages

I
.........
3/8" Lag
.... _
...........Screw
,,
..............
__ (not supplied)
5/8
Washer .........
(supplied)
i _[-_
....
I
......
Shim Und_er _
Surf_ace Line
Washer
Concrete Anchor
(not supplied)
(not supplied)
6.
Place ,the (4) 3/8" lag screws
through
the air compressor
feet,
washers,
shims,
and into the
anchors.
7.
Torque
3/8" lag screws
to
7 - 10 ft. Ibs.
Wiring Instructions
Improper
electrical
installation
of this
product
may void its warranty
and
your fire insurance.
Have circuit
wiring
performed
by qualified
personnel
such as a licensed
electricians
who
is familiar
with the current
national
electrical
code and any prevailing
local
electrical
codes.
Une mauvaise
connexion
6tectrique
de ce produit
pourrait
annuler
la garantie
et votre
assurance
contre
les incendies.
A qualified
electrician
needs to knows
the following
before
wiring:
t.
The amperage
rating
of the electri-
cal box should
be adequate.
Refer
to the Specification
Chart for this
information.
2.
The supply
line should
have the
same electrical
characteristics
(voltage,
cycle,
phase) as the
motor.
Refer to the motor name-
plate, on side of motor, for this
information.
NOTE:
The wiring must
be the same
as the motor nameplate
voltage
plus
or minus
10%. Refer to local codes
for
recommended
wire sizes, correct
wire
size, and maximum
wire run; undersize
wire causes
high amp draw and over-
heating
to the motor.
_Risk
of Electrical
Shock. Electrical
wiring must be located away from
hot surfaces such as manifold
assembly, compressor outlet tubes,
heads, or cylinders.
GROUNDING
INSTRUCTIONS
This product
should
be connected
to
a metallic,
permanent
wiring
system,
of an equipment-grounding
terminal
or lead on the product.
Voltage
and Circuit
Protection
Refer to the specification
chart for the
voltage
and minimum
branch
circuit
requirements.
Risk of Unsafe
Operation.
Certain
air compressors
can be operated
on a 15 amp circuit if the following
conditions
are met.
1.
Voltage
supply
to circuit
must
comply
with the National
Electrical
Code.
2.
Circuit
is not used to supply
any
other
electrical
needs.
3.
Extension
cords
comply
with
specifications.
4.
Circuit
is equipped
with a 15 amp
circuit
breaker
or 15 amp time
delay fuse.
NOTE:
If compressor
is connected
to a circuit
protect-
ed by fuses,
use only time delay
fuses. Time delay fuses
should
be
marked
"D" in Canada
and "T" in
the US.
if any of the above
conditions
cannot
be met, or if operation
of the com-
pressor
repeatedly
causes
interruption
of the power,
it may be necessary
to
operate
it from a 20 amp circuit.
It is
not necessary
to change
the cord set.
Air Distribution
System
Risk of Bursting.
Plastic
or PMC
pipe is not designed
for use with
compressed
air. Regardless
of its
indicated
pressure
rating,
plastic
pipe can burst
from
air pressure.
Use only
metal
pipe for air
distribution
lines.
11- ENG