Craftsman 919.165611 Owner's Manual
Craftsman 919.165611 Owner's Manual

Craftsman 919.165611 Owner's Manual

Permanently lubricated twin v 2-stage stationary air compressor
Hide thumbs Also See for 919.165611:
Table of Contents

Advertisement

Available languages

Available languages

Owner's Manual
Permanently Lubricated
Twin V
2-Stage
Stationary

AIR COMPRESSOR

Model No.
919.165611
• Safety Guidelines
• Assembly
• Operation
• Maintenance
• Troubleshooting
• Repair Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
D29312
Rev. 1
6/12/03

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Craftsman 919.165611

  • Page 1: Air Compressor

    • Assembly • Operation • Maintenance • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman D29312 Rev. 1 6/12/03...
  • Page 2: Table Of Contents

    If this air compressor is used for commercial or rental purposes, the warranty will apply for ninety days (90) from the date of purchase. This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province.
  • Page 3: Specification Chart

    SPECIFICATION CHART Model No. 919-165611 Max. Developed HP Bore 2.375 Stroke-High Pressure .54” Low Pressure 1.45” Voltage-Single Phase 240/60/1 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity - Gallons Approximate Cut-in Pressure Approximate Cut-out Pressure SCFM@ 40 psig SCFM@ 90 psig SAFETY GUIDELINES - DEFINITIONS...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. HAZARD WARNING: Risk of explosion or fire What Could Happen How To Prevent It Always operate the compressor in a well...
  • Page 5 HAZARD WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Drain tank daily or after each use.
  • Page 6 HAZARD WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with properly it may cause electric shock.
  • Page 7 HAZARD WARNING: Risk of Burns What Could Happen How To Prevent It Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 HAZARD WARNING: Risk of Serious Injury or Property Damage When Transporting Compressor (Fire, Inhalation, Damage to Vehicle Surfaces) What Could Happen How To Prevent It Oil can leak or spill and could result in Always place COMPRESSOR on a fire or breathing hazard; serious injury or protective mat when transporting to death can result.
  • Page 9: Glossary

    GLOSSARY When the tank pressure drops to a Become familiar with these terms certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called “cut-in”...
  • Page 10: Assembly

    ASSEMBLY It may be Contents of Carton necessary to brace 1 - Air Compressor or support one side of the outfit 1 - Parts bag containing: when removing the pallet because 1 - Operator’s Manual the air compressor will have a 1 - Parts Manual tendency to tip.
  • Page 11 Place the (4) washers (supplied) GROUNDING INSTRUCTIONS between the floor and air This product should be connected to compressor feet. If needed, solid a metallic, permanent wiring system, shims may be placed between of an equipment-grounding terminal the washers and floor to evenly or lead on the product.
  • Page 12: Air Distribution System

    • Use pipe that is the same size as • A flexible coupling is the air tank outlet. Piping that is recommended to be installed too small will restrict the flow of between the air discharge outlet air. and main air distribution line to allow for vibration.
  • Page 13: Operation

    OPERATION Know Your Air Compressor READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Tank Pressure Gauge: The tank Description of Operation pressure gauge indicates the reserve Become familiar with these controls...
  • Page 14: How To Use Your Unit

    Check Valve: When the air How to Use Your Unit compressor is operating, the check How to Stop: valve is “open”, allowing compressed Set the On/Auto/Off lever to air to enter the air tank. When the air “OFF”. compressor reaches “cut-out” pressure, the check valve “closes”, Before Starting allowing air pressure to remain inside...
  • Page 15 Check for excessive vibration. How to Start Readjust or shim air compressor Turn the On/Auto/Off lever to feet, if necessary. “AUTO” and allow tank pressure After 15 minutes, close the globe to build. Motor will stop when valve. The air receiver will fill to tank pressure reaches “cut-out”...
  • Page 16: Maintenance

    MAINTENANCE Customer Responsibilities Daily or Before Every after each Frequently Yearly each hours Check Safety Valve Drain Tank Air Filter Inspect air lines and fittings for leaks Air compressor pump intake and exhaust valves 1- more frequent in dusty or humid conditions Unit cycles To Check Safety Valve automatically when...
  • Page 17 Water will NOTE: If the air filter is extremely condense in the air dirty it will need to be replaced. Refer tank. If not drained, water will to the “Repair Parts” for the correct corrode and weaken the air tank part number.
  • Page 18: Service And Adjustments

    SERVICE AND ADJUSTMENTS Unit cycles Outlet Tube automatically when power is on. When doing Pressure Relief Maintenance, you may be exposed Check Tube to voltage sources, compressed air Valve or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure.
  • Page 19: Storage

    STORAGE Water will Before you store the air compressor, condense in the air make sure you do the following: tank. If not drained, water will Review the "Maintenance" corrode and weaken the air tank section on the preceding pages causing a risk of air tank rupture. and perform scheduled After the water has been drained, maintenance as necessary.
  • Page 20: Troubleshooting

    TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
  • Page 21 PROBLEM CAUSE CORRECTION Operate safety valve Possible defect in safety Knocking Noise. manually by pulling on ring. valve. If valve still leaks, it should be replaced. Defective check valve. Remove and clean, or replace. Prolonged excessive use of Decrease amount of air Compressor is air.
  • Page 22 PROBLEM CAUSE CORRECTION Motor will not Motor overload protection Let motor cool off and run. overload switch will switch has tripped automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch “cut-in” below “cut-in” pressure of pressure.
  • Page 23 CONTENIDO GARANTÍA ............26 CUADRO DE ESPECIFICACIONES .
  • Page 24: Cuadro De Especificaciones

    CUADRO DE ESPECIFICACIONES Modelo Nº 919-165611 Máx. HP desarrollado Diámetro interior 2,375 pulg. (6,03 mm) Carrera- Alta Presión .54 pulg. (1,37mm) Baja Presión 1,45 pulg. (3,7 mm) Tensión monofásica 240V/60/1 Circuito mínimo requerido Tipo de fusible Acción retardada Capacidad de aire en el tanque 60 Galones ( 227,1litros) Presión de corte de entrada Presión de corte de salida...
  • Page 25 INSTRUCCIONES IMPORTANTES DE SEGURIDAD GUARDE ESTAS INSTRUCCIONES La operación o el mantenimiento inadecuados de este producto podrían ocasionar serias lesiones y daños a la propiedad. Lea y comprenda todas las advertencias e instrucciones de funcionamiento antes de utilizar este equipo. PELIGRO ADVERTENCIA: Riesgo de Explosión o Incendio qué...
  • Page 26 PELIGRO ADVERTENCIA: Riesgo de Explosión Tanque de aire: las siguientes condiciones podrían, causar el debilitamiento del tanque, y determinar su explosión violenta, daños a la propiedad o serias lesiones. qué puede occurrir cómo prevenirlo Drene el tanque diariamente o después de Drenaje inadecuado del agua condensada cada uso.
  • Page 27 PELIGRO ADVERTENCIA: Riesgo de Descarga Eléctrica qué puede occurrir cómo prevenirlo Su compresor de aire está accionado por Jamás opere el compresor a la intemperie electricidad. Como cualquier otro dispositivo cuando está lloviendo o en condiciones de eléctrico impulsado eléctricamente, si no se lo humedad.
  • Page 28 PELIGRO ADVERTENCIA: Riesgo de Quemaduras qué puede occurrir cómo prevenirlo Jamás toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente después del compresor o los tubos de salida del de la operación. el compresor permanecerá escape, puede ocasionarle serias caliente por varios minutos luego de la quemaduras.
  • Page 29 PELIGRO ADVERTENCIA: Riesgo de Serias Lesiones o Daños a la Propiedad al Transportar el Compresor (Fuego, inhalación, daño a la superficie de vehículos) qué puede occurrir cómo prevenirlo Deposite el compresor sobre una alfombrilla El aceite puede derramarse y ello podría protectora cuando lo transporte.
  • Page 30: Glosario

    GLOSARIO Presión mínima de corte: Cuando el Familiarícese con los siguientes términos, motor está apagado, la presión del tanque antes de operar la unidad: de aire baja a medida que usted continúa CFM: (Cubic feet per minute) Pies cúbicos usando su accesorio. Cuando la presión por minuto.
  • Page 31: Instalación

    ENSAMBLADO Desembalaje Contenido de la Caja Extraiga todo el embalaje 1 - Compresor de aire Podrá ser 1 - Bolsa de piezas conteniendo lo necesario siguiente: apuntalar o soportar un lado del equipo 1 - Manual del operador al extraer la plataforma, porque el 1 - Manual de piezas compresor de aire tenderá...
  • Page 32 Haga coincidir la alineación de los INSTRUCCIONES PARA orificios de la superficie, con el de las CONECTAR A TIERRA patas del compresor de aire. Este artefacto debe conectarse al terminal Coloque las (4) arandelas metálico de un sistema de cableado (suministradas) entre el piso y las permanente a tierra para equipos o al patas del compresor.
  • Page 33 La siguiente imagen representa un se pudiese acumular y congelar. sistema típico de distribución de aire. Las Efectúe pruebas de presión antes de siguientes son pautas para tener presente cubrir la cañería, a fin de asegurarse al montar el sistema de distribución del que todas las uniones de la misma compresor de aire.
  • Page 34: Operación

    OPERACIÓN Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicación de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 35 Válvula reguladora: Cuando el Cómo utilizar su unidad compresor de aire se encuentra funcionando, la válvula reguladora esta Cómo detenerla: "abierta", permitiendo la entrada del aire Coloque la posición de la llave comprimido al tanque de aire. Cuando el interruptora On/Auto/Off en la nivel de presión del tanque alcanza el posición "OFF".
  • Page 36 Verifique la existencia de vibración Cómo poner en marcha excesiva. Reajuste o acuñe el pie del compresor, si ello fuera necesario. Mueva la palanca On/Auto/Off a la posición "AUTO" y deje que se Luego de 15 minutos, cierre la incremente la presión del tanque. El válvula de asiento.
  • Page 37: Mantenimiento

    MANTENIMIENTO Responsabilidades del cliente Antes Diariamente Cada Anualmente Frecuentemente o luego de cada cada uso horas Verifique la válvula de seguridad Drenaje del tanque Filtro de aire Inspección de eventuales fugas en las cañerías de aire y las conexiones. Válvulas de entrada y escape de la bomba del compresor de aire 1- Más frecuente en condiciones polvorientas o húmedas.
  • Page 38 Drene el agua contenida en el tanque Filtro de de aire, abriendo la válvula de aire drenaje ubicada en la base del tanque (en sentido contrario a las agujas de reloj). Dentro del Tapa del tanque se filtro de aire producirá...
  • Page 39: Servicio Y Ajustes

    SERVICIO Y AJUSTES La unidad cicla Tubo de Tuerca automáticamente salida en cuanto la energía eléctrica es Válvula conectada. Al efectuar el Tubo aliviador regula- mantenimiento, usted quedará de presión dora expuesto a tensión viva, aire comprimido o partes en movimiento. Debido a tales circunstancias, podrían ocurrirle lesiones personales.
  • Page 40: Almacenaje

    ALMACENAJE Antes de guardar su compresor de aire, El agua se asegúrese de hacer lo siguiente: condensa dentro del tanque de aire. Si no se drena, ella Revise la sección "Mantenimiento" corroerá debilitando las paredes del de las páginas precedentes y ejecute tanque de aire, originando un riesgo de el mantenimiento programado de ruptura de sus paredes.
  • Page 41: Guía De Diagnóstico De Problemas

    GUÍA DE DIAGNÓSTICO DE PROBLEMAS El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes de aire comprimido que podrían ocasionar lesiones personales. Antes de intentar reparación alguna, desenchufe el compresor de aire y purgue toda la presión de aire del tanque.
  • Page 42 CAUSA CORRECCIÓN PROBLEMA Posible defecto en la válvula Opere la válvula de seguridad Golpeteo. de seguridad. manualmente tirando de su anillo. Si la válvula aun pierde, deberá ser reemplazada. Posible defecto en la válvula Extraiga y limpie o reemplace. de seguridad. El compresor no Excesivo y prolongado uso del Disminuya la cantidad de uso de...
  • Page 43 PROBLEMA CAUSA CORRECCIÓN El motor no Deje enfriar el motor y el El interruptor de protección des interruptor de sobrecarga se funciona. obrecarga del motor se ha reajustará automáticamente. abierto. El motor arrancará automáticamente La presión del tanque excede cuando la presión del tanque caiga la presión de "corte máximo"...
  • Page 44: Notes/Notas

    NOTES/NOTAS 49- SP D29312...
  • Page 45 NOTES/NOTAS 50- SP D29312...
  • Page 46 NOTES/NOTAS 51- SP D29312...
  • Page 47 Get it fixed, at your home or ours! Your Home For repair – in your home – of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner’s manuals that you need to do-it-yourself.