Craftsman 919.165570 Owner's Manual
Craftsman 919.165570 Owner's Manual

Craftsman 919.165570 Owner's Manual

Permanently lubricated single stage portable air compressor

Advertisement

Available languages

Available languages

Owner's Manual
i (RRFTSMRNq
Permanently
Lubricated
Single Stage
Portable
AIR COMPRESSOR
Model No.
919.165570
Safety Guidelines
Assembly
Operation
Maintenance
Service
and Adjustments
Troubleshooting
Repair
Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears, Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
A00844
Rev. 0
12/07/03

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 919.165570

  • Page 1 • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman A00844 Rev. 0 12/07/03...
  • Page 2: Table Of Contents

    HOW TO ORDER REPAIR PARTS ...... back cover ltl__1 ;| ;[_I_ hi" FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge.
  • Page 3: Specification Chart

    Model No. 919.165570 Max. Developed Running HP Bore 2.375" Stroke 1.35" Voltage-Single Phase 120V/60HZ Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig [.'-Yzl = _ li'l_l] Im]=1 II I#I =[_'].,I m] = 1 = I#lil II[o _]_:] This manual contains information that iS important for you to know and understand.
  • Page 4 I1_I_o];]lL"_ +Ill [,,'9'-'I _1 _ i'dl I +F,,,_11_o _+]L_,[,,I Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. ,I;1"1.,I;I n WARNING: Risk of explosion or fire How To Prevent It What Could Happen...
  • Page 5 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. How To Prevent It What Could Happen Failure to properly drain Drain tank daily or after each use.
  • Page 6 WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions, powered device, If it is not used properly Never operate compressor with it may cause electric shock.
  • Page 7 WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENT IT Touching exposed metal such as the Never touch any exposed metal parts on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns, hot for several minutes after operation.
  • Page 8 WARNING: RISK OF UNSAFE OPERATION WHAT CAN HAPPEN HOW TO PREVENT IT Review and understand all instructions Unsafe operation of your air compressor and warnings in this manual. could lead to serious injury or death to Become familiar with the operation and you or others.
  • Page 9: Glossary

    Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Assembly

    Assemble Wheels Contents of Carton 1 - Air Compressor It will be necessary to brace or support Wheels one side of the air compressor when installing the wheels because 2 - Shoulder Bolts, 3/8 the compressor will have a Hex Nuts, 3/8 tendency to tip.
  • Page 11: Installation

    I I_[411v;_ II Ir;'ul[o_J HOW TO SET UP YOUR This plug MUST be used with a grounded outlet. UNIT IMPORTANT: The outlet being used Location of the Air Compressor must be installed and grounded in accordance with all local codes and Locate the air compressor in a clean, ordinances.
  • Page 12 Extension Cords Voltage and Circuit Protection Refer to the Parts Manual for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Risk of Unsafe and overheating.
  • Page 13: Operation

    Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Tank Pressure Gauge Outlet Switch Pressure i...
  • Page 14 Motor Overload Protector: The Air Compressor Pump (not shown): Compresses air into the air tank. motor has an automatic reset thermal Working air is not available until the overload protector. If the motor compressor has raised the air tank overheats for any reason, the pressure above that required at the overload protector will shut off the air outlet.
  • Page 15 Move the On/Auto/Off lever to How to Start: "ON/AUTO" position. The Turn the On/Auto/Off lever to compressor will start. "ON/AUTO" and allow tank Run the compressor for 15 pressure to build. Motor will minutes. Make sure the drain stop when tank pressure reaches valve is open and there is "cut-out"...
  • Page 16: Maintenance

    Customer Responsibilities Before Daily ol after Every Every aach each Yearly hours "_ours Check Safety Valve • Drain Tank • Air Filter 0(1) • Air compressor pump intake and exhaust valves • 1- more frequent in dusty or humid conditions Risk of Unsafe To Check Safety...
  • Page 17 After the water has been drained, IMPORTANT: Do not operate the close the drain valve (clockwise). compressor with the air filter removed. The air compressor can now be stored. If dirty, rinse air filter with warm NOTE: If drain valve is plugged, water and squeeze dry.
  • Page 18: Service And Adjustments

    An maintenance and repair Unscrew the check valve (turn operations not listed must be counterclockwise) using a 7/8" performed by Trained Service open end wrench. Note the Technician. orientation for reassembly. Using a screwdriver, carefully Risk of Unsafe push the valve disc up and Operation.
  • Page 19 To Replace Regulator Assemble the regulator and orient as shown. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. Set the On/Auto/Off lever to "OFF" and unplug unit. Remove the outlet pressure gauge and adapter from the regulator.
  • Page 20: Storage

    Before you store the air compressor, Risk of Bursting. Water will make sure you do the following: condense in the air tank. If not Review the "Maintenance" drained, water will corrode and section on the preceding pages weaken the air tank causing a risk and perform scheduled of air tank rupture and possible maintenance as necessary.
  • Page 21: Troubleshooting Guide

    d:{ollJ :] il ::F-"] -" [oIo]l III _[I Risk of Unsafer Operation. Performing repairs may expose voltage sources, moving parts, or compressed air sources. Personal injury may occur. Before servicing: Unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 22 PROBLEM CAUSE CORRECTION Pressure reading It is normal for "some" If there is an excessive on the regulated )ressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 23 PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Let motor cool off and Motor overload protection run. overload switch will switch has tripped. automatically reset. Motor will start automatically Tank pressure exceeds pressure switch "cut-in"...
  • Page 24: Repair Parts

    ._ I-'I_o]_V_l *_ -'! _o] -II m] ¥,___,__ _ v Air Compressor Model Number 919.165570 1Tore Je 15-25 tn-Lbs Torque 100-120 In-Lbs 9-12 Ft-Lbs Torque 5-7 Ft-Lbs 15-25 In-Lbs A00844 24_ENG...
  • Page 25 Nut Sleeve Assembly 3/8" AC-0774 Isolator (3) AC-0292 Outlet Tube SSP-7821-1 Nut Tubing 3/8" OD SSG-3105 O-Ring Pump Assembly A00850 Label, Craftsman LA-3027 Label, Drain Tank Eng/Spa LA-3108 Label, Hot Surface SST-107 Recess Rubber Bumper (2) SSF-630 Screw (2) D23565 Label, Star Rating D23138 Wheel 9"...
  • Page 26 Air Compressor Model Number 919.165570 The picture shown is for reference only, It may differ from actual unit, Torque 7-10 Ft-Lbs S% orqoo,l-03,o-Lbo Torque 42-48 tn-Lbs Torque100-1201n-Lbs 70_\__ Torque 100-120 In-Lbs A00844 26_ ENG...
  • Page 27 Air Compressor Model Number 919.165570 PART NUMBER DESCRIPTION SSF-586 Screw 1/4-20 UNC x .75 AC-0108 SSF-615 Screw 1/4-20 UNC x 1.25 Z-AC-0140 Eccentric Bearing Assembly Z-A00852 Motor >x 78 Cylinder Sleeve > 79 Connecting Rod Assembly >x79-2 Formed Compression Ring >...
  • Page 28: Espai_Iol

    GARANT|A TOTAL DE UN AI_IO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra, Sears, a su opei6n, Io reparar& o reemplazar& sin eosto alguno.
  • Page 29 Modelo N ° 919.165570 Max. HP desarrollado HP de Trabajo Di&metro interior 2,375 po (60,4ram) Carrera 1,35 po (34,3mm) Tensi6n monofasica 120V/60HZ Circuito mfnimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire an el tanque 30 Galones (113,6 Iitros) Presi6n de corte de entrada Presi6n de corte de salida 7,8 Calibre de libras SCFM a 40 psig...
  • Page 30 GUARDE ESTAS INSTRUCCIONES LA OPERACI()N O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODR|AN OCASIONAR SERIAS LESIONES Y DAI_IOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. ',,I = ll [_ ;{+ ADVERTENCIA: RIESGO DE EXPLOSION O INCENDIO &COMO PREVENIRLO? &QUE...
  • Page 31 ',,I::41 [ _ r,{+ ADVERTENCIA: RIESGO DE EXPLOSION TANQUE AIRE: SIGUIENTES CONDICIONES PODRiAN, CAUSAR DEBILtTAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSION VIOLENTA, DAI_IOS A LA PROPIEDAD O SERIAS LESIONES. &QUE PUEDE OCURRIR? _.COMO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamenta o despu_s en el tanque,...
  • Page 32 ADVERTENCIA: RIESGO DE DESCARGA ELECTRICA &QUEPUEDE OCURRIR? &COMO PREVENIRLO? Su compresor de aire est& accionado per Jam&s opere el compresor a la intemperie cuando est& Iloviendo o en condiciones electricidad. Come cualquier otto dispositivo humedad. et_trico impulsado electricamente, si no se Io utiliza adecuadamente, podrla causarle Nunca opere el compresor...
  • Page 33 ADVERTENCIA: RIESGO DE QUEMADURAS _QU I_ PUEDE OCURRIR? _.COMO PREVENIRLO? Jamds toque partes de metal expuestas en el Tocar el metal expuesto tal eomo el cabezal compresor durante o inmed+atamente despues del compresor o los tubos de saIida del escape, de la operaci6n, el compresor permanecer_ puede ooasionarle...
  • Page 34 ADVERTENCIA: RIESGO DE OPERACION INSEGURA _fC6MO PREVENIRLO? _QUEPUEDE OCURRIR? La operacion insegura de su compresor de aire Revise y comp_enda todas las instrucciones podrla ocasionarle serias lesiones o la muerte advertencias COntenidss en este msnuai. a usted u otros. Familiarlcese con los m_todos de operaci6n control del compresor de aire.
  • Page 35 Presibn minima de corte: Cuando el Familiarfcese con los elguiantes t_rminos, motor est& apagado, la presiSn del tanque antes de operar la unidad: de aire baja a medida que usted contint_a OFM: (Cubic feet per minute) Pies cQbicos usando su accesorio Cuando la presi6n por minuto.
  • Page 36 Ensamble de las ruedas Contenido de la caja Sera necesario 1- Compresor de aire soportar un lado 2- Ruedas del equipo cuando se instalan las ruedas porque el compresor tender_ 2- Pernos con resalto, 3/8 pulg. voltearse. 2- Tuercas hexagonales, 3/8 pulg.
  • Page 37 COMO PREPARAR LA UNIDAD AsegOrese de que el tomaconie_te que set& utilizado tenga la misma con_uracidn que el enchufe de conexidn Ubicacibn del compmsor de aire atierr& Ubique al compresor de airs en una zona NO UTILICE UN ADAPTADOR. Ver limpi&...
  • Page 38 Cables de extensi6n el_ctrica Proteccibn del voltaje y del circuito No se recomienda la utilizaci6n de cables Acerca del voltaje y la mfnima cantidad de extension electric& El uso de cables circuitos requeridos, refi_rase al cuadro de extension electrica originara una caida de especifieaciones.
  • Page 39 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaelones Conserve este manual para referencias futuras.
  • Page 40 autom&ticamente una vez enfriado el motor< Bomba de compresibn del aire (no mostrada): Comprime el aire dentro del Si el protector de sobrecarga apaga el tanque. El elre de trabajo no se encueotra motor con mucha frecuencia, vetifique si disponible hasta que el compresor haya hay algt_n pesible problema de veltaje.
  • Page 41 Cbmo poner en marcha: Antes de cada puesta en marcha: Mueva la paianca On/Auto/Off a la Coloque el interruptor On/Auto/Off en la posici6n "ON/AUTO" y deje que se posici6n "OFF" y cierre el regulador de incrementela presi6n del tanque. El aire.
  • Page 42 Responsabilidades del cliente Antes Diadanente Cada Cada Anualmente de cada o luego de cada use horas horas Verifique la v&lvula de seguridad Drenaje de{ tanque O(1) • Filtro de aire Valvulas de entrada y escape de la bomba del compresor de aire 1- M&s frecuente en condiciones...
  • Page 43 Extraiga el reten del filtro de aire. Riesgo de Explosibn. Dentto Retire el flltro de aire y aseg_rese de del tanque se ptoducita condensacidn que este limpio. de agua. Si no drena, el agua Io tMPORTANTE: NO opere el compresor cortoerd y debilitard causando un sin el filtro de aire.
  • Page 44 Todo tipo de mantenimiento y Desenrosque la v&lvula de retenci6n operaciones de reparacibn no gir&ndola hacia la izquierda usando mencionados, deberan set efectuados una Ilave de boca de 7/8 plug. por personal t_cnico especializado. (22 ram). Tome nota de la orientaci6n para volverla a ensamblar.
  • Page 45 Ensamble el regulador y orientelo de Para reemplazar el regulador acuerdo a Io mostrado. Libere toda la presi6n del aire del tanque. Yea "Drenaje del tanque" en la secci6n _Mantenimiento". 2< Apagar la unidad colocando interruptor en On/Auto/Off en "OFF ". Usando una Ilave de tuercas ajustable retire el medidor de presi6n de salida y el adaptador...
  • Page 46 Antes de guardar su compresor de aire, Riesgo de Explosibn. El asegQrese de hacer Io siguiente: agua se condensa dentro del tanque de 1< Revise la secci6n _Mantenimiento" aire. Si no se drena, ella de las p&ginas precedentes y ejecute corroera debilitando la paredes del el mantenimiento...
  • Page 47 [_l_.,_ Im] _ I m] p ';l_] Z [T_"-]lli[o,,[o] I m] " _ I _ :To]=]nil = 1 i_Y;%,."] Riesgo de Operacibn Insegura: La unidad arranca automaticamente cuando esta enchufade. AI hacer el mantenimiento, el operader puede queder expuesto a fuentes de corriente y de aire comprimido o a piezas movibles.
  • Page 48 PROBLEMA CORRECCI6N CAUSA Si habiese una caida excesiva de La lectura de la ESnormal que ocurra algQn presi6n durante el uso del descenso en la presi6n. presi6n sobre an accesorio, ajaste el regulador man6metro acuerdo alas instrucciones de la viene equipado secci6n Operaci6n.
  • Page 49 CAUSA CORRECCI(_N PROBLEMA El motor no El interruptor de protecci6n Deje enfriar el motor y el funciona. interruptor de sobrecarga se obrecarga del motor se ha abierto< reajustar& autom&ticamente El motor arrancar& automaticamente La presi6n del tanque excede la presion de "corte maximo" cuando la presi6n del tanque caiga For debajo de la presi6n de corte del interruptor...
  • Page 50: Notes/Notas

    A00844 50 -SP...
  • Page 51: Repair Protection Agreements

    Preteccibn para Reparaciones Congratulations on making a smart Felicitaciones per hater una compra purchase. Your new Craftsman '_ product is inteligente, Su nueva unidad Craftsman ® est& designed and manufactured for years of diseffada y fabricada para afros de operaci6n dependable operation.
  • Page 52 Your Home For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.

Table of Contents