HOW TO USE YOUR GENERATOR
If you have any problems operating your generator,
please call the generator helpline at 1-800-222-3136.
Grounding
the Generator
The National Electrical Code requires that the frame
and external electrically conductive parts of this
generator be properly connected to an approved earth
ground. Local electrical codes may also require proper
grounding of the unit. For that purpose, a grounding
wing nut is provided on the base of the cradle (note:
typical unit shown may not look like your unit).
k
Generally, connecting a No. 12 AWG (American Wire
Gauge) stranded copper wire to the grounding wing
nut and to an earth-driven copper or brass grounding
rod (electrode) provides adequate protection against
electrical shock. However, local codes may vary
widely. Consult with a local electrician for grounding
requirements
in your area.
Proper grounding of generator will help prevent
electrical shock in the event of a ground fault condition
in the generator or in connected electrical devices.
Proper grounding also helps dissipate static electricity,
which often builds up in ungrounded devices.
BEFORE STARTING
THE
GENERATOR
To operate the engine you must do the following:
Add Engine Oil
NOTE: When adding oil to the engine crankcase in
the future, use only high quality detergent oil rated
with API service classification SF or SG SAE 30
weight. Use no special additives.
Select the oil's viscosity grade according to your
expected operating temperature. Do Not use
SAE 10W-40.
Above 40°F, use SAE 10W-30 or SAE 30.
Below 40°F, use synthetic 5W-20 or 5W-30.
_F -20
C-30
0
20
32 40
60
80
100
-2'0
-io
6
i'o
2'0
4'0
Temperature Rangeof Expected Use
Although multi-viscosity oils (5W30, 10W30, etc.)
improve starting in cold weather, these multi-viscosity
oils will result in increased oil consumption when used
above 32°F. Check your engine oil level more
frequently to avoid possible damage from running low
on oil.
Place generator on a level surface.
Clean area around yellow oil fill cap. Remove the
oil fill cap.
Slowly fill engine with oil through the oil fill opening
until the oil level is to the point of overflowing.
Install yellow oil fill cap and finger tighten securely.
Check engine oil level before starting each time
thereafter. If the oil level is below the point of
overflowing, fill to the proper level.
Add Gasoline
,_
WARNING!
Never fill fuel tank indoors. Never
fill fuel tank when engine is running or hot. Do
Not light a cigarette or smoke when filling the
fuel tank.
,_
CAUTION!
Do Not overfill the fuel tank.
Always leave room for expansion.
Use regular UNLEADED gasoline with the
generator engine. Do Not use premium gasoline.
Do Not mix oil with gasoline.
Clean area around fuel fill cap, remove cap.
Slowly add unleaded regular gasoline to fuel tank.
Be careful not to overfill. Allow about 1/2" of tank
space between bottom of fill opening and top of
fuel for fuel expansion, as shown here.
1/2" Air Space
Tank
Fuel
Install fuel cap and wipe up any spilled gasoline.
IMPORTANT:
It is important to prevent gum deposits
from forming in essential fuel system parts such as the
carburetor, fuel filter, fuel hose or tank during storage.
Also, experience indicates that alcohol-blended
fuels
(called gasohol, ethanol or methanol) can attract
moisture, which leads to separation and formation of
acids during storage. Acidic gas can damage the fuel
system of an engine while in storage. To avoid engine
problems, the fuel system should be emptied before
storage of 30 days or longer. See "Storage" on
page 12. Never use engine or carburetor cleaner
products in the fuel tank or permanent damage may
Occur.