Craftsman 580.327130 Operator's Manual

3500 watt ac generator
Hide thumbs Also See for 580.327130:

Advertisement

Available languages

Available languages

Operators Manual
CRRFT$14RN °
3500 Watt
AC Generator
Model No
580.327130
C usGemneraHt°lpl ine_"
HOURS:
Mon.- Fri. 8 a.m. to 5 p.m. (CT)
CAUTION:
Before using this product,
read this
manual and follow all its Safety Rules
and Operating
Instructions
Sears, Roebuck
and Co,
Hoffman
Estates,
IL 60179
Visit our Craftsman website: www.sears.com/craftsman
Part No. B2541 Draft 4 (03/28/2000)
Safety
Assembly
Operation
Maintenance
Parts
Espahol

Advertisement

Table of Contents
loading

Summary of Contents for Craftsman 580.327130

  • Page 1 • Assembly manual and follow all its Safety Rules and Operating Instructions • Operation • Maintenance • Parts Sears, Roebuck and Co, Hoffman Estates, IL 60179 • Espahol Visit our Craftsman website: www.sears.com/craftsman Part No. B2541 Draft 4 (03/28/2000)
  • Page 2 WARRANTY ........TROUBLESHOOTING ......SAFETY RULES ....... SCHEMATIC DIAGRAM ......ASSEMBLY ........WIRING DIAGRAM ......OPERATION ........ REPLACEMENT PARTS ..... 16-21 MAINTENANCE ......8-11 EMISSION CONTROL WARRANTY ..... 22-23 SPECIFICATIONS ......ESPANOL ......... 24-39 STORAGE ........HOW TO ORDER PARTS ....BACK PAGE LIMITED WARRANTY FOR DELUXE PORTABLE...
  • Page 3 • Never add fuel while unit is running. • Allow at least 2 feet of clearance on all sides of The engine exhaust from this product contains generator while operating unit or damage could chemicals known to the State of California result.
  • Page 4 CARTON CONTENTS TO REMOVE GENERATOR FROM CARTON • Main unit • Owner's manual • Slice two corners at end of carton from top to • Engine oil bottom so the panel can be folded down flat, then remove all packing material. Check all contents.
  • Page 5 KNOW YOUR GENERATOR Read the owner's manual and safety rules before operating your generator. Compare the illustrations with your Generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. Fuel Tank Air Cleaner Fuel Shut Off Run/Stop Switch Choke Lever...
  • Page 6 HOW TO USE YOUR GENERATOR • Place unit on a level surface. • Clean area around oil fill and remove oil dipstick. If you have any problems operating your generator, • Wipe dipstick clean. please call the generator helpline at 1-800-222-3136. •...
  • Page 7 • Let engine run at no-load for several minutes to stabilize the internal temperatures of engine and WARNING! temperature of muffler and nearby areas may exceed 150°F (65°C). Avoid these generator. areas. • Move Run/Stop switch to "Stop" position. • Unplug all electrical loads from generator receptacles before starting the engine.
  • Page 8 LOW OIL PRESSURE SHUTDOWN DON'T OVERLOAD SYSTEM GENERATOR The engine is equipped with a low oil pressure sensor Overloading a generator in excess of its rated wattage that shuts down the engine automatically when the oil capacity can result in damage to the generator and to pressure drops below 6 psi.
  • Page 9 MAINTENANCE SCHEDULE Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below. Every 8 Hours 25 Hours or 50 Hours or 100 Hours or Yearly Maintenance Operation or Daily Every Season Every Season Every Season...
  • Page 10 A vacuum cleanermaybeusedto pickuploose Retorque Head Bolts dirtanddebris. After 50 hours of operation, retorque the head bolts for Lowpressure a ir(notto exceed 25 psi)maybe this engine to 3.1 kg/m (22 foot-pounds). The torque usedto blowawaydirt.Inspect c ooling airslots sequence is A, B, C, D, E (star pattern). andopenings onthegenerator.
  • Page 11 • Cleanaircleaner c overtheninsert p re-cleaner i nto • Remove the four screws attaching the valve cover cover.Nextinsert n ewpaperfilterintocoverto with a #2 or #3 phillips screwdriver. holdpre-cleaner in place andassemble a ll ofthem • Make sure the piston is at Top Dead Center (TDC) to thebaseof theaircleaner.
  • Page 12 GENERAL Engine The generator should be started at least once every Change Oil seven days and allowed to run at least 30 minutes. If While engine is still warm, drain oil from crankcase. this cannot be done and you must store the unit for Refill with recommended grade.
  • Page 13 PROBLEM CAUSE CORRECTION 1. Resetcircuitbreaker. Engine isrunning,butno 1. One ofthe circuitbreakersis open. ACoutput isavailable. 2. Fault in generator. 2. ContactSearsservicefacility. 3. Poorconnectionor defectivecordset. 3. Checkand repair. 4. Connecteddeviceis bad. 4. Connectanotherdevicethat is in good condition. Shortcircuitin a connectedload. Disconnect s hortedelectricalload. Enginerunsgoodat no-loadbut "bogs down"whenloadsare connected.
  • Page 14 CRAFTSMAN 3500 Watt AC Generator 580.327130 BRIDGE RECTIFIER BLUE FIELD BLUE POWER POWER GRAY (11) (44) C.B. C.B. 120 VAC L _RAA_ BLUE_ (11A) (44A)-- BLUE GRAY --(11A) 120/2@0...
  • Page 15 CRAFTSMAN 3500 Watt AC Generator 580.327130 SCREW PANEL C.B. C.B, GRAY GRAY BLUE GRAY BLUE BLUE BLUE GRAY GRAY CAUTION!I! OUTLET MUST BROKEN OFF IF OUTLET IS REPLACED_ BLUE BLUE >< +__ BRUSHES NOTE: :*POSITIVE BRUSH CLOSEST TO BEARING...
  • Page 16 CRAFTSMAN 3500 Watt AC Generator 580.327130 Main Unit m Exploded View DETAIL " X " DETAIL " Y " _" DETAIL " Y "...
  • Page 17 CRAFTSMAN 3500 Watt AC Generator 580.327130 Main Unit m Parts List Item PaN # Qty. Description Item Part# Qty. Description B97195 86292 CRADLE, XL SCREW, #10 x 16 Self Drilling 84021 77395 SUPPORT, Engine NUT, M6 Flange Lock 66365 83465...
  • Page 18 ENGINE, 7 HP, Generac Power Systems, EHC 00955 - Low Oil Shutdown Governor- Exploded View and Parts List 11./1_ ' Item Item Part# Part# Qty. Description Qty. Description 45756 M6 x 10 mm Screw 78653 Run/Stop Switch 72347 85272 L.E.D. Assembly Spark Plug 84195 Low Oil Shutdown Decal...
  • Page 19 ENGINE, 7 HP, Generac Power Systems, EHC 00955 - Recoil Starter and Flywheel Exploded View and Parts List 90 88 Item Part # Qty. Description 82774 Woodruff Key 77182E Flywheel 83312 Conical Washer 81810 M16 Hex Nut 92984 Top Wrapper 45756 M6 x 10 mm Screw 78609...
  • Page 20 ENGINE, 7 HP, Generac Power Systems, EHC 00955 - Carburetor, Air Cleaner, Switch and Oil Filter-Exploded View and Parts List Item Pan # Item Qty. Description Part # Qty. Description 94820 78631 Manifold Gasket Expansion Plug 91848 Oil Filter Gasket 97747 Carburetor 84982...
  • Page 21 ENGINE, 7 HP, Generac Power Systems, EHC 00955 - Long Block - Exploded View and Parts List Item Part # Qty. Description Item Part # Qty. Description 78621 Control Rod Assembly 78606 M6-1.0 x 12 mm Screw 76389 Piston Pin 76361 Governor Gear Thrust Washer 88411...
  • Page 22 CALIFORNIA EMISSION CONTROL Owner's Warranty Responsibilities WARRANTY STATE M E NT As the small off-road engine owner, you are responsible for the performance of the required Your Warranty Rights and Obligations maintenance listed in your owners manual. Sears recommends that you retain all receipts covering The California Air Resources Board ("CARB") and maintenance on your small off-road engine, but Sears Sears Roebuck and Co., USA, are pleased to explain...
  • Page 23 WHAT IS COVERED WHAT IS NOT COVERED All failures caused by abuse, neglect, or improper Repair or Replacement of Parts maintenance are not covered. • Repair or replacement of any warranted part will be Add-on or Modified Parts performed at no charge to the owner at an approved Sears servicing center.
  • Page 24 LIMITADA DE GENERADOR PORTATILE CRAFTSMAN SEARS garantiza al comprador original que el alternador y el motor para su generador portatil estaran libres de defectos en los materiales o la mano de obra para las piezas y el periodo establecido a partir de la fecha de compra original. Esta...
  • Page 25 • La gasolina es altamente INFLAMABLE y sus vapores son EXPLOSIVOS. No permita que fumen, que existan llamas abiertas, chispas o calor a su alrededor cuando manipule gasolina. Evite regar gasolina sobre un motor caliente. Cumpla con todas las regulaciones requieran almacenamiento y manejo de gasolina.
  • Page 26 PARA RETIRAR EL GENERADOR • Corte las esquinas en una de las terminaciones de las caja de envio y acueste la caja por ese lado. DE LA CAJA • Retire el material de empaque, rellenos de la caja, etc. • Saque los repuestos que continen ambas cajas y caja de •...
  • Page 27 CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIO Y LAS REGLAS DE SEGURIDAD ANTES DE OPERAR SU GENERADOR. Compare las ilustraciones con su Generador para familiarizarse con las ubicaciones de los diferentes controles y ajustes. Conserve este manual para referencias futuras. Tanque de Combustible Toma de 120/240 Voltios AC,...
  • Page 28 COMO USAR SU GENERADOR A pesar de que los aceites de mQItiple viscosidad (5W30, 10W30, etc.) mejoran el arranque en clima frio, estos Si tiene problemas operando su generador, por favor Ilame pueden producir un aumento en el consumo de aceite a la linea de ayuda para generadores al 1-800-222-3136.
  • Page 29 produce la separaci6n y formaci6n de acidos durante el • Cuando el motor arranque, mueva la palanca del almacenamiento. La gasolina acida puede daSar el sistema cebador a la "Media" estrangulaci6n" hasta que el motor de combustible de un motor durante su almacenamiento. funcione suavemente y despu6s muevala a la posici6n de "Funcionamiento".
  • Page 30 SISTEMA DE PARADA POR BAJA NO SOBRERECARGE PRESION DEL ACEITE GENERADOR El motor esta equipiado con un sensor de baja presi6n del El sobrecargar un generador en exceso de su capacidad aceite que para automaticamente el motor cuando la presi6n clasificada de vatiaje puede resultar en dafio al generador y a los dispositivos el6ctricos conectados al mismo.
  • Page 32 RESPONSIBILADES DEL CLIENTE Cada 8 Horas o Cada 25 Horas Cada 50 Horas Cada 100 Horas o Cada ASo Trabajo de Mantenimiento Diariamente o Estacional o Estacional Estacional Revise el de Acietel Cambie el aceite del motor :I: Umpie la Malla del Apagachispas Servido para El Depurador de Aire Servido para El Depurador de Aire Ajuste del Espacio Libre de...
  • Page 33 • Instale el tap6n de Ilenado del aceite y asegQrelo. Para limpiar el Generador: • Limpie cualquier derrame de aceite. • Utilice un trapo hQmedo para limpiar las superficies exteriores. Limpie/reemplace La Bujia • Puede usar un cepillo de cerdas suaves para retirar la Cambie la bujia cada 100 horas de operaci6n o una vez al suciedad endurecida, aceite, etc.
  • Page 34 NOTA: El generador tendra que tener un apagachispas si Io Proporcione Servicio al Depurador de Aire usa en terrenos no tratados cubiertos de monte, maleza o Su motor no funcionara correctamente y podria resultar pasto. El apagachispas debera ser mantenido en buenas daSado si Io hace funcionar con un depurador de aire sucio.
  • Page 35 • Aseg6rese de que el pist6n est6 en el Punto Muerto Cuando la separaci6n de las vMvulas sea la correcta, Superior (PMS) de su recorrido de compresi6n (ambas sostenga el pasador de bola pivote en su posici6n con la valvulas cerradas). Para Ilevar el pist6n al punto muerto Ilave allen y apriete la contratuerca del brazo oscilante.
  • Page 36 GENERALIDADES Cambio de Aceite Con el motor todavia caliente, drene el aceite de la caja del El generador debera ser encendido al menos una vez cada cig0eSal. Vuelva a Ilenarlo con el grado de aceite siete dias y debera dejarlo funcionar al menos durante recomendado.
  • Page 37 PROBLEMO ACClON CAUSA 1. Reposicione elinterruptor. El interruptor automatico de circuito esta abierto. Averia en el generador. Contacte el Departmento de Servicio El motor esta funcionando Sears. pero no existe salida de CA Conexi6n mal o defectuosa deljuego Revise y repare. disponsible.
  • Page 38 DECLARACION DE LA GARANTIA Responsabilidades de Garantia Propietario DEL CONTROL DE EMISIONES Como propietario de un motor ULGE, usted es responsable CALIFORNIA Y TERRITORIOS por el cumplimiento del mantenimiento exigido, el cual se FEDERALES encuentra listado en su Manual del Propietario suministrado por la fabrica.
  • Page 39 QUE ESTA CUBIERTO POR LA Partes Agregadas o Modificadas GARANTiA El uso de partes agregadas, modificadas o no autorizadas puede ser motivo suficiente para negar un reclamo de garantia. Sears no sera responsable por reparaciones de Reparacion o Reemplazo de Partes este tipo.
  • Page 40 For in-home major brand repair service: Call 24 hours a day, 7 days a week 1-800-4-MY-HOME (1-800-469-4663) Para pedir servicio de reparacibn a domicilio - 1-800-676-5811 In Canada for all your service and parts needs call - 1-800-665-4455 Au Canada pour tout le service ou les pieces For the repair or replacement parts you need: Call 7 am - 7 pm, 7 days a week 1-800-366-PART...

Table of Contents