20 ISDN Primary Rate Interface equipment overview
64 Kbit/s Clear Data Hardware
The QMT21 High Speed Data Module (HSDM) is required in the clear-data
pathway to support the 64Kbit/s clear-data function. One module is required
at each system end of any connection.

D-Channel Handler description

This section provides descriptions of the D-Channel (DCH) cards, the MSDL
card, and the Downloadable D-Channel Daughterboard.

NT6D11 DCH

Power requirements
The power requirements for the NT6D11AB/11AE/AF DCH are:
DCH/PRI interface
The NT6D11AB/AE/AF DCHs connect to the PRI2 cards by means of a
special RS422 cable, the QCAD328A, which is a special RS422 cable; refer
to
"QCAD328" (page 300)
DCH faceplate
NT6D11AB/AE/AF DCHs have one Light Emitting Diode (LED), to indicate
an active or inactive state, and two external connectors:
Figure 2 "NT6D11 DCH faceplate layout" (page 21)
layout.
Copyright © 2003-2007, Nortel Networks
.
QMT8 Asynchronous Data Module (ADM), QMT11 Asynchronous/Syn-
chronous Interface Module (ASIM) or QMT21 High Speed Data Module
(HSDM)
Data line card
+5 volts at 3 amperes
+12 volts at 75 milliamperes
-12 volts at 75 milliamperes
Port J1 is a standard asynchronous port providing an interface for
non-PRI applications.
Note: This connection will not support an Add-on Data Module (ADM)
terminal.
Port J2 is the D-Channel Interface port.
Nortel Communication Server 1000
ISDN Primary Rate Interface Installation and Commissioning
NN43001-301 02.03 Standard
Release 5.5 7 December 2007
of the Cabling chapter for more details.
shows the faceplate