230 Volt Operation; Extension Cords; Specifications - Craftsman 351.214140 Operator's Manual

5 x 6" band saw with stand
Table of Contents

Advertisement

Green (or green and yellow) conductor in cord is the
grounding wire. If repair or replacement of the elec-
tric cord or plug is necessary, do not connect the
green (or green and yellow) wire to a live terminal.
Where a 2-prong wall receptacle is encountered,
it
must be replaced with a properly grounded 3-prong
receptacle installed in accordance with National Electric
Code and local codes and ordinances.
WARNING:
This work should be performed by a quali-
fied electrician.
A temporary 3-prong to 2-prong grounding adapter (see
Figure 4) is available for connecting plugs to a two pole
outlet if it is properly grounded.
EXTENSION CORD LENGTH
Wire Size
A.W.G.
Up to 25 ft ..................................
18
NOTE: Using extension cords over 25 ft. long is not
recommended.
U
V
115V
Grounding Lug,
_
Make Sure
AdapteS_
This Is
3-Prong
Connected
To A Known
Ground
2-Prong Receptacle
Figure 4 - 2-Prong Receptacle with Adapter
Do not use a 3-prong to 2-prong grounding adapter
unless permitted by local and national codes and
ordinances. (A 3-prong to 2-prong grounding adapter
is not permitted in Canada.) Where permitted, the
rigid green tab or terminal on the side of the adapter
must be securely connected to a permanent electri-
cal ground such as a properly grounded water pipe,
a properly grounded outlet box or a properly ground-
ed wire system.
Many cover plate screws, water pipes and outlet boxes are
not properly grounded. To ensure proper ground, ground-
ing means must be tested by a qualified electrician.
230 VOLT OPERATION
To use the band saw with a 230V, single-phase
power supply, have a qualified electrician attach a
230 volt, 20/30A 3-prong plug onto band saw line
cord and install the proper connectors and recepta-
cles to power supply.
See wiring diagram (Figure 5) for motor wiring
instructions.
EXTENSION
CORDS
The use of any extension cord will cause some drop
in voltage and loss of power.
Wires of the extension cord must be of sufficient size
to carry the current and maintain adequate voltage.
Use the table to determine the minimum wire size
(A.W.G.) extension cord.
Use only 3-wire extension cords having 3-prong
grounding type plugs and 3-pole receptacles which
accept the tool plug.
If the extension cord is worn, cut, or damaged in any
way, replace it immediately.
U
V
B30V
1,2, 3, 4 - Motor Leads
U, V - Power Supply
Figure 5 - Motor Wiring Diagram
The 5 x 6" Horizontal and Vertical Metal Cutting Band
Saw provides speed with quality of cut for fabrication
shops, machine shops, maintenance departments
and
contractors. Blade speed ranges from 80 to 200 FPM to
cut a variety of material ranging form cast iron, tool
steel, bronze, aluminum and plastic.
The gravity controlled down feed can be controlled by
adjusting coil spring tension. Features include 00-45 °
vise for angle and miter cutting an adjustable work stop.
Saw is controlled by toggle switch.
SPECIFICATIONS
Capacity
............................
5" Rounds
5 x 6_" Rectangle at 90 °
6_ x _" Rectangle at 90 °
5_" Square at 90 °
3 x 9" Rectangle at 45 °
3" Square at 45 °
Blade speeds ................
80, 120 and 200 FPM
Blade size .......................
1/2 x .025 x 64_"
Blade wheels ..............................
73/8"
Overall dimensions:
Head in Horizontal Position ............
36 x 14 x 17"
Head in Vertical Position .............
42 x 151/2 x 56"
Weight .................................
106 Ibs
5

Advertisement

Table of Contents
loading

Table of Contents