Table 5. Switch Specifications (continued)
Specification
Frame buffers
Port to port latency
Data transmission range
Chassis type
The acceptable environmental ranges for the FC Switch 6164 are shown in
Table
6.
Table 6. FC Switch 6164 Environmental Specifications
Parameter
Temperature (operating) 10 C to 40 C
Temperature
(non-operating)
Operating humidity
Non-operating humidity 95% RH non-conducting @ 40 C
Operating altitude
Non-operating altitude
Operating shock
Non-operating shock
Operating vibration
Non-operating vibration 10G, 0–5 kHz
Description
16 buffers per port at 2112 bytes per frame
Less than 2 microseconds with no contention
Up to 500 meters (1,625 ft.) for
short-wavelength
optical link
Up to 10 kilometers (32,820 ft.) for
long-wavelength optical link
Back-to-front airflow (AC power connection
out front)
Specification
–35 C to 65 C
5% to 85% non-condensing @ 40 C
0 to 3 kilometers above sea level
0 to 12 kilometers above sea level
4G, 11MS duration, half sine
20G, 11MS duration, sq.wave
5G, 0–3 kHz
Quick Start Guide