Operating the Jukebox
Running an Internal Test
Test Name
EXERCISE MECH
WELLNESS TEST
CLEAR SOFT LOG
CLEAR HARD
LOG
PLUNGE FULL
SPD
PLUNGE 1/2 SPD
PLUNGE 1/4 SPD
STARWARS
3-32
Description
Runs the VERTICAL TEST, TRANSLATE TEST,
FLIP TEST, MAGAZINE IO, DRIVE IO, and
MAILSLOT IO tests. Each test runs one time per test
loop.
Checks the general capability of the jukebox. Requires
one loaded disk. The drives, transport, and mailslot
Runs
must be empty.
INIT MECHANICS
EXERCISE MECHANICS
.
test loop
Sets the soft error log to zero.
Sets the hard error log to zero.
Allows the disk transport mechanics to run at full
speed. This setting should always be used in normal
jukebox operation.
Used by service personnel only. Allows the disk
transport mechanics to run at half speed
Used by service personnel only. Allows the disk
transport mechanics to run at quarter speed.
The display shows 0 0 0.
Each "0" indicates one of the paths that the disk
transport mechanism follows in front of each stack of
optical disks. If the path is clear, a "0" displays; if the
path is blocked (because of an optical disk that is not
inserted fully into its storage slot for example), an "*"
will be displayed. This display is automatically updated
if the status changes.