FC-FC routing connectivity
Symptom
Host application times out.
Probable cause and recommended action
The FCR tends to take a long time, more than 5 seconds, to present and setup paths for the proxy
devices. Certain hosts are able to do discovery much faster as a result they end up timing out. Use
the speed tag feature to always present target proxy to the host and import them faster. This helps
sensitive hosts to do a quick discovery without timing out or cause an application failure.