6.2.2. UPGRADE APPLICATIONS
From the Management menu Item, select the Nodes Upgrade item:
Perform this procedure to update the applications:
x
Select the applications in the Node List
x
from the Node List button
The access status changes from: Access Denied
x
From the Applications update panel, click on Update
x
The status of the Applications with respect to the version is updated.
7. VIRTUALIZATION MODULE
7.1. INTRODUCTION
The Dell Multi UPS Management Console Virtualization Module for VM Ware and Hyper V requires
a network shutdown environment. The UPS has to be connected through a network interface (e.g.
NMC) and the protection software (DELL ULNM) has to be configured in order to communicate with
this network interface. Each peer to peer interface (i.e. USB/RS232) between Dell UPS Local Node
Manager and the UPS doesn't allow using this virtualization module.
The Dell Multi UPS Management Console Virtualization Module will retrieve information from the
Hypervisor Supervision tool database.
Dell MUMC will execute advanced features on UPS Power Events:
x
Trigger the move of the Virtual Machines to other servers (Put the VM host in maintenance
mode).
Î The data center will benefit with this zero down time feature.
x
Trigger Shutdown of the VM Host with VCenter (With SCVMM this feature is done by DELL
ULNM).
Î The data center will benefit from servers graceful shutdown.
Dell MUMC – User Guide
P 164000119 Rev 0.03
Dell Multi UPS Management Console
> Set Login Parameters, enter the access Login and Password
to Access OK
USER GUIDE