Wayne ESP45 Operating Instructions And Parts Manual

24-volt backup sump pump
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

PLEASE READ AND SAVE THESE INSTRUCTIONS. READ CAREFULLY
BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY
OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY
DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
SAFETY GUIDELINES
This manual contains information
that is very important to know
and understand. This information
is provided for SAFETY and to
PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates an imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates a potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates important
information, that if not followed,
may cause damage to equipment.

SPECIFICATIONS

Power supply requirements .......... 120V, 60 Hz
Motor .............................................. Permanent Magnet DC Motor
Normal water removal .................. 2880 GPH @5 ft. @ 26V DC
Liquid temperature range ............ 40º F to 120º F
Circuit requirements ...................... 5 amps AC (min)
Pump Dimensions .......................... 11 inch high x 8-3/4 inch base
Pump Run Time .............................. 15 Seconds
© 2010 WAYNE Pumps
DESCRIPTION
The ESP45 is a battery operated back-
up sump pump. It does not replace a
regular pump. It is designed to provide
protection in the event household
electrical power fails or main pump fails.
UNPACKING
I nspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components are
damaged, return the unit to the place of
purchase for replacement. Failure to do so
could result in serious injury or death.
GENERAL SAFETY INFORMATION
CALIFORNIA PROPOSITION 65
This product or its power cord contains
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
GENERAL SAFETY
Do not use to pump
fl ammable or explosive fl uids
such as gasoline, fuel oil,
kerosene, etc. Do not use in a fl ammable
and/or explosive atmosphere. Personal
injury and/or property damage could result.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
OPERATING
INSTRUCTIONS
AND PARTS
MANUAL
24-Volt
Backup Sump Pump
CONSTRUCTION
Motor housing .........................Cast Iron
Impeller .....................................Thermoplastic
Shaft seal ..................................Stainless Steel
Discharge ..................................1-1/2 inch NPT
Float Switch ..............................Reed Style
Disconnect power before
servicing. If the power
dis con nect is out of sight, lock
in the open po si tion and tag it to prevent
unexpected application of power. Failure to
do so could result in fatal electrical shock!
If the basement has water or moisture on
the floor, do not walk on wet area until
all power is turned off. If the shutoff box
is in the basement , call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.
All wiring must be performed by a
qualifi ed electrician.
Do not expose battery to
sparks or fl ames as an
explosion or fi re could result.
Battery acid is corrosive.
Avoid spilling on skin or
clothing. Eye protection must
be worn when handling the battery.
A check valve must be used on the
primary sump pump discharge.
353502-001 3/10
MODEL
ESP45

Advertisement

Table of Contents
loading

Summary of Contents for Wayne ESP45

  • Page 1: Operating Instructions

    Pump Run Time ......15 Seconds REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. 353502-001 3/10 © 2010 WAYNE Pumps For parts, product & service information visit www.waynepumps.com...
  • Page 2: Battery Information

    If applications and will void warranty. • The PS/BC is designed for the WAYNE acid contacts your skin or clothing, wash pump only, DO NOT Use For Any immediately with soap and water.
  • Page 3: Pump Installation

    Model ESP45 PUMP INSTALLATION Installation of this unit may take several hours. Before disabling your Floor Joist Ridgid main pump, have ready an appropriate Slope Pipe means of evacuating the sump. PVC Pipe Down 1. Turn power to main pump off. 2.
  • Page 4: Control Box Installation

    Operating Instructions and Parts Manual PUMP INSTALLATION CONTINUED Ridgid Slope Pipe Floor Joist PVC Pipe Down Be careful not to strip or cross thread plastic fi ttings or check valves. Flex hose is not recommended. Rigid PVC or metal pipe is required for a permanent installation.
  • Page 5: Operation

    Model ESP45 OPERATION CHART 2 - PS/BC STATUS LIGHTS LIGHT ON WHEN ACTION REQUIRED Low Voltage or Blown Fuse Check Fuse or Replace Batteries Always disconnect the power source before attempting to Yellow Battery OK None install, service, relocate or maintain the pump.
  • Page 6: Troubleshooting Chart

    Operating Instructions and Parts Manual TROUBLESHOOTING CHART Symptom Possible Cause(s) Corrective Action Pump won't run 1. Connections not secure 1. Check all connections 2. Low or defective battery 2. Check battery and replace if low or defective 3. Float switch stuck 3.
  • Page 7 FOR REPLACEMENT PARTS OR TECHNICAL ASSISTANCE, CALL 1-800-237-0987 Please provide following information: Address parts correspondence to: - Model number WAYNE Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Page 8: Limited Warranty

    LIMITED WARRANTY For one year from the date of purchase, WAYNE Pumps ("WAYNE") will repair or re place, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by WAYNE to be defective in materials or work man ship.
  • Page 9: Spécifications

    Temps de fonctionnement de la pompe ..15 Seconds MÉMENTO : Gardez votre preuve datée d‘achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. 353602-001 3/10 © 2010 WAYNE Pumps 9 Fr...
  • Page 10: Généralités Sur La Sécurité

    • Le chargeur fera fonctionner le pendant 10 minutes et consulter WAYNE offre une pile horaire de 40 moteur de la pompe ou chargera les immédiatement un médecin. Si l’acide ampères WSB1240 et une batterie batteries lorsqu'il est branché...
  • Page 11 Modèle ESP45 PS/BC FEATURES (suite) • Le CB/AC est conçu seulement pour la pompe de WAYNE Water Systems, il NE doit PAS être utilisé à toutes Solive autres fins. de plancher Tuyau rigide Placer le tuyau LE SYSTÈME PASSERA À L'ALARME SI:...
  • Page 12 Instructions d‘Utilisation et Manual de Pièces MONTAGE DE POMPE (suite) minimum car cela réduit l’écoulement de sortie de la pompe. Le tuyau qui sort de la structure de l’édifi ce devrait être en Tuyau rigide Tuyau rigide Solive de pente vers le bas pour que l’eau ne gèle de PVC de PVC plancher...
  • Page 13: Entretien

    Modèle ESP45 INSTALLATION DU CB/AC TABLEAU 2 - VOYANTS DE STATUT DE BC/AC (suite) VOYANT ALLUMÉ LORSQUE ACTION REQUISE Rouge Basse tension ou fusible grillé Vérifi er le fusible ou remplacer les batteries Jaune Batterie OK Aucune Toujours débrancher le c.a. et retirer le fusible de la pompe avant de brancher Vert C.a.
  • Page 14: Guide De Dépannage

    Instructions d‘Utilisation et Manual de Pièces ENTRETIEN 3. Inspecter les bornes et les colliers pour (suite) souffl er les gaz autour des batteries à la corrosion et le serrage. Nettoyer et l’aide d’un carton utilisé comme éventail. serrer au besoin. 1.
  • Page 15 POUR DES PIÈCES DE RECHANGE, COMPOSER 1-800-237-0987 S’il vous plaìt fournir l’information suivante : Correspondance : - Numéro de modèle WAYNE Pumps - Numéro de série (si applicable) 101 Production Drive - Description et numéro de pièce d’après la liste de pièces Harrison, OH 45030 U.S.A.
  • Page 16 Instructions d‘Utilisation et Manual de Pièces GARANTIE LIMITÉE For one year from the date of purchase, WAYNE Pumps ("WAYNE") will repair or re place, at its option, for the original purchase Pour un an à compter de la date d’achat, WAYNE Water Systems (“WAYNE”) vas réparer ou remplacer, à son option, pour l’acheteur originel n’importe quelle pièce ou pièces de ces Pompes De Puisard ou Pompes À...
  • Page 17: Especificaciones

    Tiempo de funcionamiento de la bomba ..15 Seconds flotador ......membrana MÉMENTO : Gardez votre preuve datée d‘achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dossier pour plus de sécurité. 353602-001 3/10 © 2010 WAYNE Pumps 17 Sp...
  • Page 18: Informaciones Generales De Seguridad

    21,6 ácido de WAYNE. Use baterías nuevas e CARACTERÍSTICAS DEL PS/BC idénticas (del mismo fabricante y de la LUCES: CIRCUITOS DE CONEXIÓN ELÉCTRICA: misma capacidad).
  • Page 19: Instalación De La Bomba

    Modelo ESP45 CARACTERÍSTICAS DEL PS/BC (continuación) BOMBA: • La bomba se encenderá cuando el Viga del interruptor de flotador se eleve. Tubo rígido Declive de piso El motor de la bomba continuará de PVC la tubería funcionando durante 15 segundos después de que baje el flotador.
  • Page 20 Manual de Instrucciones de Operación y Piezas INSTALACIÓN DE BOMBA (continuación) MÉTODO 2 Si no es posible lograr una descarga Conector separada y dedicada como en el Tubo Viga del "Y" Método 1, la bomba ESP45 puede rígido de piso conectarse a la tubería de descarga de la bomba que funciona con CA, instalando un conector "Y".
  • Page 21: Mantenimiento

    Modelo ESP45 INSTALLACIÓN DE PS/BC TABLA 2 – LUCES DE ESTADO DEL PS/BC (continuación) ENCENDIDA CUANDO ACCIÓN A TOMAR Rojo Bajo voltaje o fusible quemado Verifi que el fusible o cambie la batería ¡Riesgo de choque eléctrico! Use un Amarillo Batería bien Ninguna interruptor de circuito de descarga a...
  • Page 22: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación y Piezas MANTENIMIENTO (continued) Siga los procedimientos y programas 3. Inspeccione los bornes y abrazaderas de mantenimiento del fabricante de para determinar si hay corrosión y si manuales de instrucciones aplicables. Para reducir el riesgo de explosión de la batería, la batería.
  • Page 23 CONCESIONARIO MÁS CERCANO A SU DOMICILIO Sírvase proporcionar la suguiente información: Envíe su solicitud de repuestos a la siguiente dirección: - Número de modelo WAYNE Pumps - Número de serie (si tiene) 101 Production Drive - Descripción y número de repuesto como Harrison, OH 45030 U.S.A.
  • Page 24 GARANTÍA LIMITADA Durante un año a partir de la fecha de compra del comprador original, la compañía WAYNE Pumps ("WAYNE") reparará o re emplazará, según lo decida, cualquier pieza de esta bomba de desagüe o bomba de agua que se encuentre defectuosa debido a materiales usados o procesos de manofactura.