Operating Instructions and Parts Manual
Limited Warranty
For two years from the date of purchase, Wayne Water Systems ("Wayne") will repair or replace, at its option, for the
original purchaser any part or parts of its Sump Pumps or Water Pumps ("Product") found upon examination by Wayne to be
defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to
provide the model and serial number when exercising this warranty. All transportation charges on Products or parts
submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect,
improper installation, improper maintenance, or failure to operate in accordance with Wayne's written instructions.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO TWO YEARS FROM THE DATE OF PURCHASE. THIS IS THE
EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENS-
ES WHATSOEVER IS EXCLUDED.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of
incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you
specific legal rights, and you may also have other legal rights which vary from state to state.
In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its
suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or
revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of
substitute products, facilities, services or replacement power, downtime costs, or claims of buyer's customers for such
damages.
You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST
send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237-0987) for return
authorization and instructions.
DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.
MODEL NO. _____________________ SERIAL NO. ________________________ INSTALLATION DATE _____________________
ATTACH YOUR RECEIPT HERE
www.waynepumps.com
8
Operating Instruction and Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
24-Volt Backup
Sump
Pump
General Safety
Description
Information
The ESP45 is a battery operated back-up
sump pump. It does not replace a
CALIFORNIA PROPOSITION 65
regular pump. It is designed to provide
protection in the event household
contain chemicals known to the State of
electrical power fails or main pump fails.
California to cause cancer and birth
Unpacking
defects or other reproductive harm. Wash
hands after handling.
Inspect this unit before it is used.
GENERAL SAFETY
Occasionally, products are damaged
during shipment. If the pump or
Do not use to pump
components are damaged, return the
flammable or explosive fluids
unit to the place of purchase for
such as gasoline, fuel oil,
replacement. Failure to do so could
kerosene, etc. Do not use in a
result in serious injury or death.
flammable and/or explosive
atmosphere. Pump should only be used
Safety Guidelines
to pump clear water. Fatal injury and/or
property damage could result.
This manual contains information that
is very important to know and
understand. This information is
If the basement has water or
moisture on the floor, do not
provided for SAFETY and to PREVENT
walk on wet area until all
EQUIPMENT PROBLEMS. To help
power is turned off. If the shutoff box
recognize this information, observe the
is in the basement, call an electrician.
following symbols.
Remove pump and either repair or
replace. Failure to follow this warning
Danger indicates an
could result in fatal electrical shock.
imminently
hazardous situation which, if not avoided,
will result in death or serious injury.
Pump Specifications
Warning indicates a
Power supply requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120V, 60 Hz
potentially
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Perminent Magnet DC Motor
hazardous situation which, if not avoided,
Normal water removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2880 GPH @ 5 Feet @ 26V DC
could result in death or serious injury.
Liquid temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40°F to 120°F
Circuit requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 amps AC (min)
Caution indicates a
Pump Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 in. high x 8
potentially
Pump run time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Seconds
hazardous situation which, if not avoided,
may result in minor or moderate injury.
Pump Construction
Notice indicates
Motor housing, volute, seal plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cast Iron
important
Impeller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Thermoplastic
information, that if not followed, may
Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless Steel
cause damage to equipment.
Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Float switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reed Style
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
© 2008 Wayne Water Systems
For parts, product & service information
visit www.waynepumps.com
All wiring must be
performed by a
qualified electrician.
This product or its
Do not expose battery to
power cord may
sparks or flames as an
explosion or fire could result.
Battery acid is corrosive.
Avoid spilling on skin or
clothing. Eye protection must
be worn when handling the battery.
A check valve must
be used on the
primary sump pump discharge.
A ground fault
circuit interrupter is required.
This pump must
only be used to
pump clear water. This pump is not
designed to handle effluent, salt
water, brine, laundry discharge or any
other application which may contain
caustic chemicals and/or foreign
materials. Pump damage may occur if
used in these applications and will void
warranty.
353601-001 7/08
ESP45
3
/
in. base
4
1
/
in. NPT
2

Advertisement

loading

Summary of Contents for Wayne 24-Volt Backup Sump Pump ESP45

  • Page 1 Limited Warranty For two years from the date of purchase, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship.
  • Page 2 • The PS/BC can be left connected to near the batteries. the batteries indefinitely Dangerous • The PS/BC is designed for the Wayne hydrogen gas can be released from batteries while Water Systems pump only, DO NOT charging. Sparks can ignite the gas in Use For Any Other Purpose an enclosed space.
  • Page 3 Operating Instructions and Parts Manual Maintenance 4. Unplug the main pump and fill sump (Continued) with water until back up pump turns on. Repeat process two times to be 3. Inspect the terminals and clamps sure pump is operating normally. for corrosion and tightness.
  • Page 4 Operating Instructions and Parts Manual Pump Installation (Continued) 3. A check valve will be required in Floor the discharge line of BOTH the Joist Main AC pump and the ESP45 pump to prevent recirculation of water into the sump pit. System will 45°...

This manual is also suitable for:

Esp45