Gas Supply Requirements - KitchenAid Pro Line KGCP487JSS2 Installation Instructions Manual

36" (91.4 cm) and 48" (121.9 cm) pro line gas cooktop with all sealed burners shown for residential use only
Hide thumbs Also See for Pro Line KGCP487JSS2:
Table of Contents

Advertisement

Available languages

Available languages

Gas and Electric
Dimensions
3-prong ground-type outlet
should be located on left hand
side of cutout 8" (20.3 cm)
max. from enclosure sidewall.
10" (25.4 cm)
Gas and Electric
Connection Locations
product rating/serial tag
regulator (supplied
with product) must be
installed with arrow up
pointing at cooktop
bottom
1/2" nipple
(not supplied)
AGA or CSA approved
flexible stainless
steel gas supply line
(not supplied)
Typical Gas and Electric
14"
(35.6 cm)
Gas supply line should be
located in this area on rear or
side walls, or the supply line can
come up through the floor.
control support panel
36" (91.4 cm)
3-prong ground-type
power supply cord
regulated gas
supply line
shut off valve
(not supplied)
Connections
Copies of the standards listed may be
obtained from:
* CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
Gas supply
requirements
Note: Solid side and
bottom of cutout
enclosure not shown.
Observe all governing codes and
ordinances.
Important: Cooktop must be connected
to a regulated gas supply.
A.
local codes and ordinances. In the
absence of local codes, installations must
Front of
conform with American National
Cooktop
Standard, National Fuel Gas Code
ANSI Z223.1 — latest edition or
CANI — B149.1 or 2*.
B.
model/serial rating plate are for elevations
up to 2,000 feet (610 m). For elevations
above 2,000 feet (610 m), ratings are
reduced at a rate of 4% for each 1,000
feet (305 m) above sea level.
C.
with NATURAL gas. It is design-certified
by International Approval Services (I.A.S.)
for NATURAL and L.P. gases with
appropriate conversion. The model/serial
rating plate, located on the underside of
the burner box, has information on the
type of gas that can be used. If this
information does not agree with the type
of gas available, check with the local gas
supplier.
WARNING
Explosion Hazard
Use a new AGA or CSA approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas
connections.
If connected to LP, have a
qualified person make sure gas
pressure does not exceed 14"
water column.
Examples of a qualified person
include licensed heating
personnel, authorized gas
company personnel, and
authorized service personnel.
Failure to do so can result in
death, explosion, or fire.
This installation must conform with
Input ratings shown on the
The cooktop is equipped for use
5

Advertisement

Table of Contents
loading

Table of Contents