Replacing the Projection Lamp
7
Remove the lamp cage cover.
Turn over the projector and loosen the user service
screw that secures the lamp cage cover. Then slide
the cover in the direction of the arrow.
9
Insert the new lamp cage.
Press the lamp cage firmly into the lamp cage
compartment. Fasten the securing screws.

Resetting the lamp timer

1
Connect the power
cord.
Plug the power cord into the AC
socket of the projector.
• Reset the lamp timer only after replacing the lamp.
51
User service
screw
2
Reset the lamp timer.
While pressing ƒ, © and
ENTER on the projector, press
POWER ON on the projector.
8
Remove the lamp cage.
Remove the securing screws from the lamp cage.
Hold the lamp cage by the handle and pull it
towards you.
Securing
screw
10
Attach the lamp cage cover.
Slide the lamp cage cover in the direction of the
arrow. Then tighten the user service screw.
"LAMP 0000H" is displayed,
indicating that the lamp timer is
reset.