Ac / Dc Current Measurements - Craftsman 82312 Owner's Manual

Mini multimeter with non-contact voltage detector (ncv)
Table of Contents

Advertisement

Available languages

Available languages

AC / DC CURRENT
MEASUREMENTS
CAUTION:
Do not make current measurements
at 10 Amps
I
for longer than 30 seconds. Exceeding 30 seconds may cause
I
damage to the meter and/or the test leads.
1.
Insert the black test lead banana plug into the negative COM
jack.
2.
For current measurements
up to 200mA AC or DC, set the
function switch to the 200m AAC or ADC position and insert
the red test lead banana plug into the mA jack.
3.
For current measurements
up to 10A AC or DC, set the
function switch to the 10A AAC or 10A ADC position and
insert the red test lead banana plug into the 10A jack.
4.
Remove power from the circuit under test, then open up the
circuit at the point where you wish to measure current.
5.
Touch the black test probe tip to the negative side of the
circuit. Touch the red test probe tip to the positive side of the
circuit.
6.
Apply power to the circuit.
7.
Read the current in the display.