Relative Mode 2O; Display Backlight; Hold - Craftsman 82003 Owner's Manual

True rms multimeter
Hide thumbs Also See for 82003:
Table of Contents

Advertisement

AUTORANGING/MANUAL
RANGE
SELECTION
When
the meter
is first turned
on, it automatically
goes
into
Autoranging.
This
automatically
selects
the best range
for the
measurements
being
made
and is generally
the best mode
for
most
measurements.
For measurement
situations
requiring
that
a range
be manually
selected,
perform
the following:
1. Press
the RANGE
key. The "Auto"
display
indicator
will turn
off.
2. Press
the RANGE
key to step through
the available
ranges.
Observe
the decimal
point and units
displayed
until the
preferred
range
is located.
3. To exit the Manual
Ranging
mode
and return
to Autoranging,
press
and hold the RANGE
key for 2 seconds.
Note:
Manual
ranging
does
not apply
for the Capacitance
and
Frequency
functions.
RELATIVE
MODE
The relative
measurement
feature
allows
you to make
measurements
relative
to a stored
zero
reference
value.
A
reference
voltage,
current,
etc. can
be stored
and
measurements
made
in comparison
to that value.
The displayed
value
is the difference
between
the reference
value
and the
measured
vaJue.
1. Perform the measurement
as described in the operating
instructions.
2. Press the REL button to store (zero) the reading in the display
and the "REL" indicator will appear on the display.
3. The display will now indicate the difference between the
stored value and the measured value.
4. Press the REL button to exit the relative mode.
Note: The Relative function does not operate in the Frequency
function.
DISPLAY BACKLIGHT
Press the backlight_:,
button to turn on. The light will slowly
fade to off after approxamately
10 to 15 seconds.
HOLD
The hold function freezes the reading in the display. Press the
HOLD key momentarily
to activate or to exit the HOLD function.