V SERIES FOOD HOLDING, TRANSPORT, AND BANQUET CARTS
SYMPTOMS
POSSIBLE CAUSES
Cabinet not
Cabinet not connected
operating.
to power source.
Cabinet lighted power
switch not turned ON.
No power.
GFCI or
Moisture problem.
Ground Fault
Shorted element.
Circuit Indicator
Pinched/damaged wire.
tripped
Damaged power cord.
Cabinet is
Heating element is
connected to
faulty.
power source,
switch is ON,
Thermometer is
circuit breaker is
faulty.
ON but cabinet
is not heating.
Thermostat is faulty.
Lighted power
Power switch faulty.
switch ON but
not lit.
Dual light indicator
faulty.
Cabinet does
Defective: element,
not heat properly.
thermometer, thermostat,
switch.
Thermostat requires
adjustment.
Door not properly
sealed.
Fan not
Power switch not ON.
operating.
Fan faulty.
(VHFA9,
VHFA18 only)

TROUBLESHOOTING

REMEDY
Connect cabinet to power source.
Turn lighted power switch ON.
Check circuit breaker.
Check GFCI.
Dry moisture problem.
Check/replace element.
Check/replace wire.
Check/replace power cord.
Check/replace heating element.
Check/replace thermometer.
.
Check/replace thermostat.
Check/replace power switch.
Check/replace Dual Light Indicator.
Check/replace: element, thermometer,
thermostat, power switch.
Perform thermostat calibration.
Check/adjust door and hinge.
Check/replace door gasket.
Turn power switch on.
Check/replace fan.
15