GE Monogram ZGU365 Installation Instructions Manual

36" downdraft gas cooktops
Hide thumbs Also See for Monogram ZGU365:

Advertisement

GE Monogram
Installation
Instructions
36" Downdraft
Gas Cooktops
Models
ZGU365
®

Advertisement

Table of Contents
loading

Summary of Contents for GE Monogram ZGU365

  • Page 1 ® GE Monogram Installation Instructions 36" Downdraft Gas Cooktops Models ZGU365...
  • Page 2: Table Of Contents

    Cet appareil doit être correctement mis à la terre. Voir << Alimentation électrique >> à la page 8. CAUTION ATTENTION If you have a question concerning the installa- Proper installation is the responsibility of the tion of this product, call the GE Answer installer. Product failure due to improper ® Center Consumer Information Service at installation is not covered under the GE 800.626.2000, 24 hours a day, 7 days a week.
  • Page 3: Design Information

    Design Information G a s Downdraf t Cooktop ZGU365 Models 36" gas downdraft cooktops Available These models are shipped for natural gas operation. They can be converted to liquid propane. (Order JXLP56 conversion kit.) These gas downdraft cooktops are equipped •...
  • Page 4: Advance Planning

    Design Information G a s Downdraf t Cooktop Advance The combined installation of a downdraft vent Base Cabinet Requirements: and cooktop require careful consideration. This installation requires a 24" min. deep Planning cabinet base. The cabinet must be at least 36" Countertop Requirements: wide.
  • Page 5: Tools And Materials Required

    Cabinetry/Ductwork G a s Downdraf t Cooktop • Self-adhesive gasket • Carpenter’s square •Duct work to suit the • 5 foot AGA-certified Tools and (supplied) • Pipe wrench installation flexible metal Materials • Two clamping • Manual gas line • 1/2" NPT x 3/4" appliance connec- brackets and shut-off valve...
  • Page 6: Venting Options

    Ductwork G a s Downdraf t Cooktop Loosen Screws to • The downdraft vent is shipped with the Venting Adjust Blower discharge outlet pointing straight down and Left to Right Options can be changed to the left or right side. •...
  • Page 7: Ductwork Fittings

    * Actual length of straight duct plus duct fitting standards such as those equivalent. Equivalent length of duct pieces are based published by NFPA on actual tests conducted by GE Evaluation Engineer- ing and reflect requirements for good venting and ASHRAE. performance with any downdraft cooktop.
  • Page 8: Power Supply Locations

    Gas and Electrical Supply G a s Downdraf t Cooktop Gas supply: Power Supply Do Not Locate Gas or Electrical These cooktops are designed to operate on Connections Within Shaded Area Locations natural gas at 4" of water column pressure or on LP gas at 10"...
  • Page 9: Installation

    Installation G a s Downdraf t Cooktop • Remove the shipping materials and the Remove carton, set carton aside. The carton can be Plastic Ties Packaging used as a pad when changing or adjusting vent direction. • Remove the plastic ties on both ends at the top of the vent.
  • Page 10: Step 2: Install Ductwork

    Installation G a s Downdraf t Cooktop • The downdraft blower system is designed for length when bends or various fittings are use with 3-1/4" x 10" ductwork. It can be used. Refer to the table of equivalent lengths Step transitioned to 6"...
  • Page 11: Step 4: Install The Cooktop

    Installation G a s Downdraf t Cooktop Note: If the cooktop is installed into a 36" Step base cabinet, the pressure regulator MUST BE installed to the bottom of the cooktop before the cooktop is placed into the cabinet. Install the •...
  • Page 12: Step 5: Electrical Connections

    Installation G a s Downdraf t C ooktop • Connect the 3-pin plastic plug from the blower/motor assembly to the 3-pin plastic socket on the underside of the vent, next to Step the conduit. Electrical • Slide the metal cover over the connection and secure with screws.
  • Page 13: Step 8: Install Filters

    Installation G a s Downdraf t Cooktop To raise the vent, turn the VENT knob to RAISE/LOWER. Step • Hold the knob until the vent begins to raise. – The vent will automatically stop when it is Install fully extended. Filters •...
  • Page 14: Jxrb57 Kit, Indoor Remote Blower Location

    JXRB57 Kit For Indoor Remote Blower Locations Tools and Materials required: • Pencil • Measuring tape • Drill with appropriate bits • Nut driver • Junction box • Wire nuts • Safety glasses • 3-1/4" x 10" to 6" round transition. •...
  • Page 15 JXRB57 Kit For Indoor Remote Blower Locations Important: Save any • Remove the 4 nuts holding the blower to the Step unused parts. If the mounting plate. One nut is hidden inside appliance is relocated at the outlet. Remove blower. a later time, parts may be •...
  • Page 16 JXRB57 Kit For Indoor Remote Blower Locations Step Downdraft Connect Ductwork Duct Adapter Outlet Cover • The downdraft plenum can discharge from • Connect the plenum to the ductwork. either the right or left side. Select the side A transition is required to connect the that provides the best alignment to ductwork 3-1/4"...
  • Page 17: Jxbc57 Kit, Outdoor Remote Blower Location

    JXBC57 Kit For Outdoor Remote Blower Locations Materials Required (not supplied) • Approved liquid tight service connections for use between the wire compartment on the base and inside the structure. • 7 wire nuts or other approved connectors. • Six 5/16" dia. fasteners compatible with the type of material the base is being fastened to.
  • Page 18 JXBC57 Kit For Outdoor Remote Blower Locations • The base is designed to be mounted to studs 16" 6 Holes on 16" centers. Use the dimensions shown to For 5/16 6-11/16" Step Fastners determine the location of the ducting and wiring through the wall.
  • Page 19 JXBC57 Kit For Outdoor Remote Blower Locations • Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside Step the outlet. Remove blower. • Remove the blower mounting plate. (continued) • Remove 2 screws along the bottom of the blower box which are visible once blower Hidden plate is removed.
  • Page 20 JXBC57 Kit For Outdoor Remote Blower Locations Plenum • Use electrical cable and connectors that Provided conform to local codes (14 gauge min. is Mounting Step recommended). Use a length to reach Screws between the vent and the blower/motor Blower Connect Wire location.
  • Page 21 Notes...
  • Page 22 Notes...
  • Page 23 Notes...
  • Page 24 NOTE: While performing installations described in this book, safety glasses or goggles should be worn. To obtain specific information concerning any ® Monogram product or service, call GE Answer Center consumer information service at 800.626.2000—any time, day or night. For Monogram local service in your area, call 1-800-444-1845.