Signal Return
Pin
Pin
11
29
BUSY
30
12
13
14
15
NC
16
17
18
NC
31
16
32
Signal
Direction
OUT
OUT
OUT
AUTO
IN
FEED
C H A S S I S -
IN
ERROR
OUT
Interface Specifications
Description
A HIGH signal indicates that the printer
cannot receive data. The signal goes
HIGH in the following cases:
2) During printing
3) When PAUSE botton is pressed
4) During printer-error state.
A HIGH signal indicates that the printer is
out of paper.
Pulled up to 5 volts through 3.3 Kohm
resistance.
When this signal is LOW, the paper is
automatically fed 1 line after printing.
(The signal level can be fixed to this by
setting DIP switch 2-4 to ON.)
Not used.
Logic ground level.
Printer's chassis ground, which is
isolated from the logic ground.
Not used.
Twisted-pair return signal ground level.
When this level becomes LOW, the
printer controller is reset to its power-up
state and the print buffer is cleared. This
level is normally HIGH; its pulse width
must be more than 50 microseconds at
the receiving terminal.
This level becomes LOW when the printer
is:
2) PAUSE
3) in error state.
Technical Specifications
7-11