Clearance To Combustibles; Combustible Sidewall Clearance; Mantels; Surround Material - Temco DV5200MB Installation And Operating Manual

Direct vent zero clearance gas fireplace heater
Table of Contents

Advertisement

Clearance to Combustibles

Top of unit to ceiling* ................................36" (914 mm)
Front of unit to combustibles ....................36" (914 mm)
Appliance
Top (from standoffs) ................................0" (0 mm)
Bottom .....................................................0" (0 mm)
Side (from standoffs) ................................0" (0 mm)
Back (from standoffs) ...............................0" (0 mm)
Top of Elbow ..........................................2" (51 mm)
* Ceiling height is the minimum height of the room ceiling in front of
the fireplace measured from the top front edge of the fireplace.

Combustible Sidewall Clearance

The perpendicular combustible sidewall or mantel sup-
port leg (surround) clearance is 1³⁄₄" (45 mm) from the
edge of the recessed door opening.

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel.
For the correct mounting height and widths, refer to
Figure 5.
Noncombustible mantels and legs may be installed at
any height and width around the appliance. When using
paint or lacquer, it must be heat resistant to prevent
discoloration.
A
B
C
D
Mantel Chart
Mantel Shelf
Ref.
or Breast Plate
T177
Temco DV Mantel
Depth
Chart
12/3/03 djt
V
10" (254 mm)
W
8"
(203 mm)
X
6"
(152 mm)
Y
4"
(101 mm)
Z
2"
(51 mm)
Fig. 5 Combustible mantel minimum installation.
78674
V
W
X
Y
Z
E
Top of Louvre
Opening
Fireplace
Mantel from Top
Ref. of Louvre Opening
A
12"
(305 mm)
B
10¹⁄₂" (267 mm)
C
9"
(229 mm)
D
7¹⁄₂" (191 mm)
E
5"
(127 mm)
WARNING: Combustible objects must not be placed
on a noncombustible mantel unless the noncombustible
mantel meets the minimum height and width require-
ments for a combustible mantel.
When using materials around the face of the fireplace,
these materials must be suitable to withstand the tem-
peratures which they will encounter. Also these materi-
als must not extend out in front of the face of the unit, in
effect recessing the unit.
If the material used for surround is not flush with the
face of the unit, then the optional surround kits will not
fit properly.
It is recommended that any material used to surround
the face of the fireplace be noncombustible (i.e. ceram-
ic tile, brick, natural stone, etc.). Combustible materials
such as drywall, are permissible.
Drywall
Noncombustible Facing
Material Overlap of Front Face
Fig. 6 Surround material options.
Combustible Material
Minimum Height from
Top Opening to Mantel
Combustible Material
Above Standoff
T177
Optional Hearth
Fig. 7 Gas fireplace installation.
Materials such as cultured marble or other synthetic
materials are not recommended as they may discolor,
warp or create odor as a result of exposure to the tem-
peratures of the front of the fireplace.
Temco DV5200 Series

Surround Material

Drywall
Tile, Marble, etc.
Fireplace
Front
Flush Face Installation
(Recommended when
installing optional trim
surround kits)
T178
surround material
12/3/03 djt
2 x 4 Stud
2 x 4 Header
Standoff
T179
firplace installation
12/3/03 djt
Tile,
Marble,
etc.
Optional
Surround
Kits
Fireplace
Front
T178
T179
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents