A. PUMP DOES NOT OPERATE
1. Check GFCI for proper operation according to GFCI manufacturer's in-
structions.
2. Check for plugged impeller. Follow disassembly/assembly instructions
under "Pump Service", Page 8.
3. Consult dealer/installer or service representative.
B. IMPROPER JET ACTION
1. Check for blocked fittings. Blocked fittings will cause poor flow and poor jet
action.
2. Consult dealer/installer or service representative.
C. EXCESSIVE AIR IN SYSTEM – PUMP LOSES PRIME
1. Make sure water level in spa is at least 2" (51 mm) above top of jets with sys-
tem not operating.
2. Make sure there are no leaks in suction piping.
3. Make sure there is no vortex (whirlpool) at the suction.
4. Consult dealer/installer or service representative.
D. CIRCUIT BREAKER IN HOME PANEL TRIPS REPEATEDLY
1. Breaker must be of adequate capacity.
2. For GFCI breaker: test according to GFCI manufacturer's instructions.
3. Make sure no other lights and appliances are on circuit.
4. Consult dealer/installer or service representative.