Fujitsu Remote Management User Manual page 413

Serverview suite irmc s2/s3 - integrated remote management controller
Table of Contents

Advertisement

Configuring the iRMC S2/S3 via SCCI and scripted configuration
The SCCI is a generic application programming interface (API) defined by
Fujitsu for different Server Management Controller hardware as well as Server
Management software (e.g. ServerView Agents). It can be easily extended to
cover new commands or new configuration items. For an architectural overview
of the SCCI, see the online help of the ServerView agents.
Starting with iRMC S2 firmware 5.20A (IPv6 version), the iRMC S2/S3 supports
remote configuration and limited scripting via the /config URL in the
iRMC S2/S3.
Benefits of remote iRMC S2/S3 configuration via web-based access
Remote configuration of the iRMC S2/S3 via web-based access provides the
following benefits:
– Uses HTTP POST operation for uploading files onto the iRMC S2/S3. No
special tool is required. Any generic tool or scripting environments
supporting authenticated HTTP POST operations can be used. Sample
scripts can be found on the ServerView Suite DVD 1.
– Uses built-in authentication and authorization methods of the iRMC S2/S3
Web server.
– Supports HTTP 1.1 Basic and Digest authentication based on RFC 2617
with local iRMC S2/S3 user accounts.
– Features optional built-in strong encryption with standard HTTPS-based
access.
– Can be used with global user accounts (managed by an LDAP directory
service) and HTTP 1.1 Basic authentication.
I
If HTTP 1.1 Basic authentication is used, it is recommended that, for
encryption and confidentiality reasons, you use the HTTPS protocol
to protect the username/password combination.
– Uses a configuration file format that is based on XML. You have the option
to edit the file manually, or to export it from a reference installation or from
the Server Configuration Manager.
The configuration file can be re-used with other SCCI based installation
methods (e.g. Server Configuration Manager).
– Can be easily extended to new configuration items and new supported SCCI
commands.
iRMC S2/S3