  • Page 1 W415-0536 / B / 07.20.06 W415-0536 / B / 07.20.06...
  • Page 2 WARNINGS & SAFETY PRECAUTIONS Installation and service must be Do not store gasoline or other performed by a qualified installer, flammable vapours and liquids in the service agency or the gas supplier. vicinity of this or any other appliance. Follow the installation directions. WHAT TO DO IF YOU SMELL GAS Do not use any phone in your building.
  • Page 3: Table Of Contents

    TABLE of CONTENTS PG2-6 INTRODUCTION BLOWER REPLACEMENT Warnings and Safety Precautions Night Light Replacement Warranty DECORATIVE BRICK PANEL Dimensions General Instructions INSTALLATION General Information Care of Glass & Plated Parts AFK / WI FACE KIT 6-10 VENTING INSTALLATION Vent lengths Venting Specifi...
  • Page 4 NAPOLEON products are manufactured under the strict Standard of the world recog- nized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fi...
  • Page 5: General Instructions

    FIGURE 1 58" 46" " " 4" DIA. 7" DIA. " 21" 5" " 2" " " 14" 24" 28" 28" Provide adequate ventilation and combustion air. GENERAL INSTRUCTIONS Provide adequate accessibility clearance for servicing and THIS GAS FIREPLACE SHOULD BE INSTALLED AND SER- operating the fi...
  • Page 6: Care Of Glass & Plated Parts

    This fi replace may be installed in an aftermarket permanently CARE OF GLASS, AND PLATED PARTS located, manufactured (mobile) home, where not prohibited by local codes. Do not use abrasive cleaners to clean plated parts. Buff lightly This fi replace is only for use with the type of gas indicated with a clean dry cloth.
  • Page 7: T < 40 Feet

    DEFINITIONS ELBOW VENT LENGTH VALUES for the following symbols used in the venting calculations feet inches and examples are: 1° 0.03 > - greater than 15° 0.45 > - equal to or greater than 30° 11.0 < - less than 45°...
  • Page 8: Figure 6

    TOP EXIT / HORIZONTAL TERMINATION when (H ) > (V = 6 ft = 3 ft Simple venting confi guration (only one 90° elbow) = 5 ft = 3 + 5 = 8 ft = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft FIGURE 6 = 8 + 2.7 = 10.7 ft = 10.7 + 6 =16.7...
  • Page 9: Ft = 2 Ft

    TOP EXIT VERTICAL TERMINATION when (H ) < (V REQUIRED VERTICAL RISE IN FEET See graph to determine the HORIZONTAL VENT RUN PLUS OFFSET IN required vertical rise for the required FEET horizontal run H The shaded area within the lines represents ac- ceptable values for H and V For vent confi...
  • Page 10 FIGURE 12 W415-0536 / B / 07.20.06...
  • Page 11 INSTALLATION WALL AND CEILING PROTECTION For optimum performance it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using fl exible venting. For safe and proper operation of the fi replace, follow the venting instructions exactly. HORIZONTAL TERMINATION: A clearance to combustibles of 2"...
  • Page 12: Air Terminal Locations

    USING FLEXIBLE VENT COMPONENTS Use only approved aluminum flexible liner kits For safe and proper operation of the fi replace, follow the marked: venting instructions exactly. All inner exhaust and outer intake vent pipe joists may be sealed using either Red RTV high temp silicone seal- ant or Black high temp Mill Pac with the exception of the fi...
  • Page 13: Fireplace Vent Connection

    FIREPLACE VENT CONNECTION 1. Install the 4” diameter aluminium fl exible liner to the fi replace. Secure with 3 screws and fl at washers. Seal the joint and screw holes using the high temperature sealant FIGURE 20 (W573-0007 not provided). 2.
  • Page 14: Gas Installation

    VERTICAL VENTING INSTALLATION GAS INSTALLATION 1. Move the fi replace into position. Proceed once the vent installation is complete. Note : All gas connections must be contained within 2. Fasten the roof support to the roof using the screws the fi replace when complete. provided.
  • Page 15: Framing

    CLEARANCE TO COMBUSTIBLES FRAMING MAINTAIN THESE MINIMUM CLEARANCES TO COM- It is best to frame your fi replace after it is positioned and the BUSTIBLES: vent system is installed. Use 2x4’s and frame to local build- Fireplace framing - 0” to stand-offs (top, rear & sides) ing codes.
  • Page 16: Electrical Connection

    MANTLE CLEARANCES Combustible mantle clearance FIRESTOP can vary according to the man- tle depth. Use the graph to SPACER 2" help evaluate the clearance STUD 1" GAP FROM INSULATION SLEEVE needed. 2" GAP FROM VENTING INSULATION 2" SLEEVE FIGURE 32 STAND OFF 6"...
  • Page 17: Finishing

    Decorative brick panels must be installed before the logs. See installation instructions supplied with the panel kit. LOG PLACEMENT PHAZER logs, exclusive to Napoleon Fireplaces, provide 4. Place log #4 with the a unique and realistic glowing effect that is different in every charred branch facing installation.
  • Page 18 BLOWER REPLACEMENT 3. Remove the glass door, logs, rear log supports, brick The Napoleon PARK AVENUE comes equipped with a heat panels, air defl ector, burner assy, panel support, panel sup- circulating blower. The blower is pre-wired and is controlled by port bracket.
  • Page 19 DECORATIVE BRICK PANEL INSTALLATION 1. Carefully remove the glass door and all logs. (Refer to Rest the bottom edge of the rear panel on top the installation manual) of the rear portion of the air defl ector at the back of the fi...
  • Page 20 AFK / WI FACE KIT INSTALLATION 1. Attach screw and spacer as illustrated in Fig. 46 to the bottom of both sides of the front housing. SCREW & SPACER FIGURE 46 2. Attach the face plate bracket provided to the top edge of the front housing using 2 #8 - 1/2”...
  • Page 21 REMOTE, RECEIVER AND VALVE ACCESS BURNER ASSEMBLY REMOVAL 1a. Rectangular Front Removal Pull on the top of the optional front away from the fi replace until the male portion of the latch disengages. Tilt forward slightly and lift from the 2 shoulder screws near the bottom. 1b.
  • Page 22 OPERATION / MAINTENANCE desired fl ame height. Six fl ame levels are included, from 1 TIME OUT (minimum) to 6 (maximum). An acoustic signal from the If the appliance is turned on and the Receiver does not receive Receiver confi rms the reception of the command. any command for 3 hours, it automatically turns the appliance and the Remote Control off.
  • Page 23 5. FAN SPEED SETTING CHILD SAFETY LOCK-OUT This function controls the speed of the hot air circulating fan. This function is to deactivate con- To change the fan speed, use the UP and Down button until trol button. The function is active the cursor (small triangle) is left of the fan icon.
  • Page 24 ADDRESS SETTING PROCEDURE Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address. Press the LEFT key to exit this function. The transmitter address is required to be equal to the Receiver.
  • Page 25 FIGURE 64 W415-0536 / B / 07.20.06...
  • Page 26 OPERATING INSTRUCTIONS slight odour for a few hours. This is caused by dust particles in When lit for the fi rst time, the fi replace will emit a slight odour the heat exchanger burning off. Open a window to suffi ciently for a few hours.
  • Page 27 MAINTENANCE 3. Check to see that all burner ports are burning. Clean TURN OFF THE GAS AND ELECTRICAL POWER out any of the ports which may not be burning or are BEFORE SERVICING THE FIREPLACE. not burning properly. CAUTION: Label all wires prior to disconnection when servic- ing controls.
  • Page 28 REPLACEMENTS Contact your dealer for questions concerning prices and avail- 1. M & S ODEL ERIAL UMBER OF FIREPLACE ability of replacement parts. Normally all parts can be ordered 2. I NSTALLATION DATE OF FIREPLACE through your Napoleon dealer or distributor. 3.
  • Page 29 0:00 FEATURE SELECT ON/OFF W415-0536 / B / 07.20.06...
  • Page 30 TROUBLE SHOOTING GUIDE EFORE ATTEMPTING TO TROUBLESHOOT PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN SYMPTOM PROBLEM TEST SOLUTION Main burner fl ame Blockage in vent. - remove blockage. In really cold conditions, ice buildup may occur on is a blue, lazy, the terminal and should be removed as required.
  • Page 31 SYMPTOM PROBLEM TEST SOLUTION - connect a jumper wire across the wall switch terminals; if main burner Themostat or switch is de- Pilot burning; no lights, replace switch / thermostat. fective. gas to main burner; gas knob is on ‘HI’; Wall switch wiring is defec- - disconnect switch wires &connect a jumper wire across terminals wall switch / ther-...
  • Page 32 W415-0536 / B / 07.20.06...