General Specifications - Fluke 233 Getting Started Manual

True-rms remote display digital multimeter
Table of Contents

Advertisement

233
Getting Started Manual

General Specifications

Maximum voltage between any
terminal and earth ground ........................................... 1000 V rms
W Fuse for A inputs ..................................................... 11 A, 1000 V 17000A interrupt rating Fuse
Altitude
Operating .................................................................... 2,000 meters
Storage ....................................................................... 12,000 meters
Temperature
Operating .................................................................... -10 C to +50 C
Storage ....................................................................... -40 C to +60 C
Temperature coefficient ............................................... 0.1 X (specified accuracy) / C (< 18 C or > 28 C)
Electromagnetic Compatibility (EN 61326-1:2006) .... In an RF field of 3 V/m, accuracy = specified accuracy except in temperature:
Wireless Frequency ...................................................... 2.4 GHz ISM Band 10 meter range
Relative Humidity.......................................................... Maximum noncondensing, 90 % at 35 C, 75 % at 40 C, 45 % at 50 C, 0 % to
Battery Type
Meter base.................................................................. Three AA Alkaline batteries, NEDA 15A IEC LR6
Display module ........................................................... Two AA Alkaline batteries, NEDA 15A IEC LR6
Battery Life .................................................................... 400 hrs typical (Alkaline)
Shock ............................................................................. 1 Meter drop 6 sides per IEC 61010
Safety Compliance........................................................ Complies with ANSI/ISA S82.01-2004, CSA 22.2 No. 61010-1-04 to 1000 V
Certifications ................................................................. CSA, TÜV (EN61010), P, ; (N10140),VDE, GOST
14
specified accuracy 5 C (9 F)
70 % for 40 M
range
Measurement Category III and 600 V Measurement Category IV.