Enterasys Matrix 6H352-25 Installation Manual page 51

Enterasys networks ethernet hub installation guide
Table of Contents

Advertisement

Switch 6 – Forced BootP.
NOTE: After changing the position of Switch 6, DO NOT reapply power to the module
until there is a station on the network acting as a BootP server, which contains the
downloadable firmware image file.
DO NOT attempt a Forced BootP unless a BootP server has been configured for the module.
The BootP server references the location of a station acting as a Trivial File Transfer Protocol
(TFTP) server containing the module image file.
When the position of Switch 6 is changed and the power is cycled to the module, the device
requests the image file location from the BootP server and uses TFTP to download the image
from the TFTP server. If one of these requirements is not met, the module continues to request
either the BootP server or the TFTP server until the RESET button on the module is pressed.
Once the RESET button is pressed, the module resets after one minute and loads the image
stored in FLASH memory.
Switch 7 – Clear NVRAM. Changing the position of this switch resets NVRAM on the next
power-up of the device. All user-entered parameters, such as the IP address, device names, etc.,
are reset to the factory default settings. Once the module resets, you can either use the factory
default settings or reenter your own parameters.
Switch 8 – Reset Password/Community Names. Changing the position of this switch clears
user-entered passwords stored in NVRAM, and restores the factory default passwords on the
next power-up of the device. Once the module resets, you can either use the factory default
settings or reenter your own passwords.
NOTE: Do not change the position of Switch 8 unless it is necessary to reset the
super-user configured passwords to their factory default settings.
Mode Switch Bank Settings and Options
Setting the Mode Switches
B-3