LIGHTING
INSTRUCTIONS:
DVCF407B_
DVCF408B_
DVCF557B_
DVCF558B
FOR YOUR
SAFETY
READ
BEFORE
LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing
property
damage,
personal
injury
or loss of life.
A.
This appliance is equipped with an ignition device which
automatically lights the pilot.
Do not try to light the
pilot by hand.
B.
BEFORE LIGHTING, smell all around the appliance area
for gas. Be sure to smell next to the floor because some
gas is heavier than air and will setting on the floor.
If you cannot reach your gas supplier, call the fire
department.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch: do not use any phone
in your building.
hmnediately
call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
C.
Use only your hand to push in or slide the gas control
lever. Never use tools. If the lever will not push in or
slide by hand, don't try to repair it, call a qualified
service technician. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been
water. Ilnmediately call a qualified service
under water.
LIGHTING
INSTRUCTIONS
1.
STOP! Read the int\_rlnation on the safety label.
2.
Set the therlnostat to it's lowest setting.
3.
Turn off all electric power to the appliance.
a.
This appliance is equipped with an iNlition device which
automatically lights the pilot.
Do not try to light the
pilot by hand.
5.
Remove cabinet door.
5.
Push in gas control lever slightly and slide right _ to
"OFF".
Maxhnum (High)
Pressure Regulator
i i-" __oJ
II
Gas Control
• o_
__
NOTE: Lever
l
can not be
ovedto
'OFF unless
iN
I v
] it is pushed
d
_
in slightly. Do
not force.
[
Step Pressure Regulator
Wait five (5) minutes to clear out any gas. Then small
t\_rgas, including near the floor. If you smell gas, STOP!
Follow "B" in the inforlnation on the safety label. If you
don't smell gas, go to the next step.
8.
Slide gas control lever left _ to "ON".
Maximuln (High)
Pressure Regulator
Gas Control
Lever
Step Pressure Regulator
9.
Replace cabinet door.
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting.
12. If the appliance
will not operate,
t\_llow the
instructions
"TO
TURN
OFF
GAS
TO
APPLIANCE" and call your service technician or
gas supplier.
TO TURN
OFF
GAS TO APPLIANCE
1.
Turn therlnostat to it's lowest setting.
2.
Turn off all electric power to the appliance if service is to be pert\tuned.
3.
Remove cabinet door.
4.
Push in gas control lever slightly and slide _ to "OFF". Do not force.
5.
Replace cabinet door.