8.10.29 CF_FILTIMER Command

Command
"CF_FILTIMER_%1"[CR]
"100" -------------------- Set 100 hours
"200" -------------------- Set 200 hours
"300" -------------------- Set 300 hours
"OFF" ------------------- No warning display
%1
"UP" --------------------- Switch Filter timer forward
"DN" --------------------- Switch Filter timer backward
Details
Set timer of Filter warning display.
Acceptable
Response
Unacceptable

8.10.30 CF_FILH Command

Command
"CF_FILH_%1"[CR]
%1
"RST" ---------------Reset Filter used time
Details
Reset filter used time
Acceptable
Response
Unacceptable

8.10.31 CF_FDEFAULT Command

Command
"CF_FDEFAULT_%1"[CR]
%1
"RST"
Set the value to Factory Default
Details
This command is available in normal Power ON status.
Acceptable
Response
Unacceptable
ÿ Off →100 → 200 → 300 → Offÿ
ÿ Off → 300 → 200 → 100ÿ
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]
"000"[CR]
"Error Code"[CR]