D-Link DSN-6120 User Manual page 120

Dsn-6100 series d-link iscsi ip san storage
Table of Contents

Advertisement

INFO
BBM status good
INFO
BBM status
charging
WARNING
BBM status fail
INFO
BBM enabled
INFO
BBM inserted
INFO
BBM removed
JBOD events
Level
INFO
PD upgrade started
INFO
PD upgrade
finished
WARNING
PD upgrade failed
INFO
PD freed
INFO
PD inserted
Warning
PD removed
ERROR
HDD read error
ERROR
HDD write error
ERROR
HDD error
ERROR
HDD IO timeout
INFO
JBOD inserted
WARNING
JBOD removed
WARNING
SMART T.E.C
WARNING
SMART fail
INFO
PD dedicated spare
INFO
PD global spare
ERROR
Config read fail
ERROR
Config write fail
WARNING
PD read error
WARNING
PD write error
INFO
PD scrub started
INFO
PD scrub completed
WARNING
PS fail
INFO
PS normal
WARNING
FAN fail
INFO
FAN normal
WARNING
Volt warn OV
WARNING
Volt warn UV
WARNING
Volt crit OV
WARNING
Volt crit UV
Battery backup module is good
Battery backup module is charging
Battery backup module is failed
Battery backup feature is <string>.
Battery backup module is inserted
Battery backup module is removed
Type
JBOD <name> PD [<string>] starts upgrading firmware
process.
JBOD <name> PD [<string>] finished upgrading firmware
process.
JBOD <name> PD [<string>] upgrade firmware failed.
JBOD <name> PD <slot> has been freed from RG <name>.
JBOD <name> disk <slot> is inserted into system.
JBOD <name> disk <slot> is removed from system.
JBOD <name> disk <slot> read block error
JBOD <name> disk <slot> write block error
JBOD <name> disk <slot> is disabled.
JBOD <name> disk <slot> gets no response
JBOD <name> is inserted into system
JBOD <name> is removed from system
JBOD <name> disk <slot>: S.M.A.R.T. Threshold Exceed
Condition occurred for attribute <string>
JBOD <name> disk <slot>: Failure to get S.M.A.R.T
information
Assign JBOD <name> PD <slot> to be the dedicated spare
disk of RG <name>.
Assign JBOD <name> PD <slot> to Global Spare Disks.
Config read error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
Config write error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
Read error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
Write error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
JBOD <name> PD <slot> starts disk scrubbing process.
JBOD <name> PD <slot> completed disk scrubbing process.
Power Supply of <string> in JBOD <name> is FAIL
Power Supply of <string> in JBOD <name> is NORMAL
Cooling fan of <string> in JBOD <name> is FAIL
Cooling fan of <string> in JBOD <name> is NORMAL
Voltage of <string> read as <string> in JBOD <name> is
WARN OVER
Voltage of <string> read as <string> in JBOD <name> is
WARN UNDER
Voltage of <string> read as <string> in JBOD <name> is
CRIT OVER
Voltage of <item> read as <string> in JBOD <name> is
CRIT UNDER