D-Link DSN-6120 User Manual page 118

Dsn-6100 series d-link iscsi ip san storage
Table of Contents

Advertisement

ERROR
SATA PRD mem fail
ERROR
SATA revision id fail
ERROR
SATA set reg fail
ERROR
SATA init fail
ERROR
SATA diag fail
ERROR
Mode ID fail
ERROR
SATA chip count
error
INFO
SAS port reply error
INFO
SAS unknown port
reply error
INFO
FC port reply error
INFO
FC unknown port
reply error
EMS events
Level
INFO
Power install
ERROR
Power absent
INFO
Power restore
ERROR
Power fail
WARNING
Power detect
INFO
Fan restore
ERROR
Fan fail
INFO
Fan install
ERROR
Fan not present
ERROR
Fan over speed
WARNING
Thermal level 1
ERROR
Thermal level 2
ERROR
Thermal level 2
shutdown
ERROR
Thermal level 2
CTR shutdown
WARNING
Thermal ignore
value
WARNING
Voltage level 1
ERROR
Voltage level 2
ERROR
Voltage level 2
shutdown
ERROR
Voltage level 2 CTR
shutdown
INFO
UPS OK
WARNING
UPS fail
ERROR
UPS AC loss
ERROR
UPS power low
WARNING
SMART T.E.C.
WARNING
SMART fail
WARNING
RedBoot failover
WARNING
Watchdog
shutdown
WARNING
Watchdog reset
Failed to init SATA PRD memory manager
Failed to get SATA revision id
Failed to set SATA register
Core failed to initialize the SATA adapter
SATA Adapter diagnostics failed
SATA Mode ID failed
SATA Chip count error
SAS HBA port <number> reply terminated abnormally
SAS frontend reply terminated abnormally
FC HBA port <number> reply terminated abnormally
FC frontend reply terminated abnormally
Type
Power(<string>) is installed
Power(<string>) is absent
Power(<string>) is restored to work.
Power(<string>) is not functioning
PSU signal detection(<string>)
Fan(<string>) is restored to work.
Fan(<string>) is not functioning
Fan(<string>) is installed
Fan(<string>) is not present
Fan(<string>) is over speed
System temperature(<string>) is higher.
System Overheated(<string>)!!!
System Overheated(<string>)!!! The system will auto-
shutdown immediately.
The controller will auto shutdown immediately, reason
[ Overheated(<string>) ].
Unable to update thermal value on <string>
System voltage(<string>) is higher/lower.
System voltages(<string>) failed!!!
System voltages(<string>) failed!!! The system will auto-
shutdown immediately.
The controller will auto shutdown immediately, reason
[ Voltage abnormal(<string>) ].
Successfully detect UPS
Failed to detect UPS
AC loss for system is detected
UPS Power Low!!! The system will auto-shutdown
immediately.
Disk <slot> S.M.A.R.T. Threshold Exceed Condition occurred
for attribute <string>
Disk <slot>: Failure to get S.M.A.R.T information
RedBoot failover event occurred
Watchdog timeout shutdown occurred
Watchdog timeout reset occurred