Instructions for the Installer

The oven is designed to be connected to
230 V (50 Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows:
Letter L
-
Letter N
-
or E
-
THIS OVEN MUST BE
EARTHED.
The cable used to connect the oven to
the electrical supply must comply to the
specifications given below.
For UK use only
Connection
Min. size Cable / flex Fuse
via
Cable/flex type
13 A socket
2.5 mm
outlet
13 A spur box
Oven
2.5 mm
Control
Circuit
For Europe use only
Min. size Cable/ Cable / flex type
flex
2
1.5 mm
Live terminal
Neutral terminal
Earth terminal
2
3 core
butyl
insulated
2
PVC/PVC
twin and
earth
Fuse
H07 RN-F, H05 RN-F, 13 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a minimum
gap of 3mm between the switch contacts
and of a type suitable for the required load
in compliance with the current rules.
The switch must not break the yellow and
green earth cable at any point.
the yellow and green earth cable should
be 2-3 cm longer than the other cables.
Important
After installation and connecting, the cable
must be placed so that it cannot at any
point reach a temperature of more than
60°C above the ambient temperature.
Before the oven is connected, check that
the main fuse and the domestic installation
can support the load and that the power
supply is properly earthed.
The manufacturer declines any
responsibility should these safety
measures not be carried out.
13 A min.
15 A min.
20 A max.
electrolux 23