Hitachi SJ300-EL Series Instruction Manual Supplement page 29

Inverter for elevator applications three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for SJ300-EL Series:
Table of Contents

Advertisement

Function mode
Code
Function name
Resume on FRS cancellation
b088
mode
b090
BRD usage ratio
b091
Stop mode selection
b092
Cooling fan control
b095
BRD selection
b096
BRD ON level
b098
Thermistor selection
b099
Thermistor error level
b120
Braking control selection
Waiting time for
releasing
b121
braking conformation
b122
Waiting time for acceleration
b123
Waiting time for stop
Waiting
time
for
signal
b124
conformation
*b125
Releasing frequency
b126
Releasing current
*b127
Brake OFF frequency
Delay time at brake signal is
b128
turned OFF
C091
Debug mode selection
C102
Reset selection
C111
Overload advance notice level
C121
O zero adjustment
C122
OI zero adjustment
C123
O2 zero adjustment
H001
Autotuning selection
st
H002
1
motor constant selection
st
H003
1
allowable motor selection
st
H004
1
motor pole selection
st
H005
1
speed response setting
st
H006
1
stabilized factor
st
H020
1
motor constant R1
st
H021
1
motor constant R2
st
H022
1
motor constant L
st
H023
1
motor constant I0
st
H024
1
motor constant J
st
1
motor constant R1
H030
(Autotuning data)
st
1
motor constant R2
H031
(Autotuning data)
st
1
motor constant L
H032
(Autotuning data)
st
1
motor constant I0
H033
(Autotuning data)
st
H034
1
motor constant J
st
1
PI-control proportion gain
H050
setting
st
1
PI-control integration gain
H051
setting
st
1
P-control proportion gain
H052
setting
st
H060
1
0Hz-SLV limiter setting
PI-control proportion gain for
H070
switching
PI-control integration gain for
H071
switching
P-control proportion gain for
H072
switching
Setting range
00(0Hz start)/01(Start f-equaling)
0.0-100.0(%)
00(deceleration stop)/01(Free-run stop)
00(Always ON)/
01(ON during run, After power ON, then for 5 minutes on stop is implied.)
00(invalid)/01(valid<invalid during stop>)/02(valid<valid during stop>)
330-380/660-760(V)
00(invalid)/01(Positive temperature coefficient enable)/02 (NTC enable)
0. – 9999. (ohm)
00(Invalid)/01(valid)
0.00-5.00(s)
0.00-5.00(s)
0.00-5.00(s)
0.00-5.00(s)
0.00-99.99/100.0-400.0(Hz)
0.00*rated current-2.00*rated current(A)
0.00-400.00Hz
0.00-5.00s
00(No display)/01(Display)
00(Trip cancel during ON)/01(Trip cancel during OFF)/
02(Valid only during trip<Cancel during ON>)
0.0-2.0*rated current(A)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
0.-9999./1000-6553(10000-65530)
00(Invalid)/01(Valid(the motor does not rotate))/
02(Valid(the motor rotates))
00(Hitachi general purpose motor data)/01(Autotuning data)/
02(Autotuning data with online autotuning)
0.20-75.0(kW) <0.2-160kW>
2/4/6/8(pole)
0.001-9.999/10.00-65.53
0. - 255.
0.000-9.999/10.00-65.53(ohm)
0.000-9.999/10.00-65.53(ohm)
0.00-99.99/100.0-655.3(mH)
0.00-99.99/100.0-655.3(A)
0.001-9.999/10.00-99.99/100.0-9999.(kgm
0.000-9.999/10.00-65.53(ohm)
0.000-9.999/10.00-65.53(ohm)
0.00-99.99/100.0-655.3(mH)
0.00-99.99/100.0-655.3(A)
0.001-9.999/10.00-99.99/100.0-9999.(kgm
0.00-99.99/100.0-999.9/1000.(%)
0.00-99.99/100.0-999.9/1000.(%)
0.01-10.00
0.-100.(%)
0.00-99.99/100.0-999.9/1000.(%)
0.00-99.99/100.0-999.9/1000.(%)
0.00-10.00
29
Chapter 3 – Parameter Setting Tables
Initial data
360/720
0.10* rated
current of
Inverter rated
forwarding
forwarding
forwarding
forwarding
forwarding
forwarding
forwarding
forwarding
2
)
forwarding
forwarding
forwarding
forwarding
forwarding
2
)
forwarding
remarks
00
0.0
00
01
00
00
3000.
01
0.10
0.40
0.40
0.00
0.00
inverter
0.00
0.50
00
00
current
Set on
Set on
Set on
00
00
Set on
4
4.00
100.
Set on
Set on
Set on
Set on
Set on
Set on
Set on
Set on
Set on
Set on
100.0
100.0
1.00
100.
100.0
100.0
1.00