1.2.9 Electrical Specifications

Item
Rated Voltage
Input Voltage
Range
Rated Frequency
Range
Input Frequency
Range
Rated Current
Power
Consumption
Insulation
Resistance
Dielectric
Strength

1.2.10 Environmental Conditions

Condition
Temperature
Humidity
Shock
Resistance
Vibration
Resistance
Note)
1:
Applicable when the unit is in a shipping container.
2:
Without condensation.
3:
The unit should be operated within the range shown in figure below.
Rev. A
Table 1-7. Electrical Specification
120V Version
120 VAC
103.5
132 V
50
60 Hz
49.5
60.5 Hz
0.5 A
(Max. 0.5 A)
Approx. 15 W
(ISO/IEC10561 LETTER pattern)
10 M , Min.
(applying 500 VDC between AC
line and chassis)
AC 1000 Vrms for 1 min. or
AC 1200 Vrms for 1 sec.
(between AC line and chassis)
Table 1-8. Environmental Conditions
Operating
10
35 C 3
20
80 % 2/3
1G
(within 1 ms)
0.15G
Humidity
(%)
80
55
20
10
Figure 1-5. Temperature and Humidity Range
Chapter 1 Product Descriptions
220
220
198
50
49.5
(Max. 0.3 A)
Approx. 15 W
(ISO/IEC10561 LETTER pattern)
Energy Star Compliant
10 M , Min.
(applying 500 VDC between AC
line and chassis)
AC 1500 Vrms for 1 min.
(between AC line and chassis)
Non operating
-20
5
(within 2 ms) 1
Temperature
27
35
(°C)
240V Version
240 VAC
264 V
60 Hz
60.5 Hz
0.3 A
60 C 1
85 % 1/2
2G
0.50G 1
1-9