Lubrication - Duerkopp Adler 550-16-23 Service Instructions Manual

Hide thumbs Also See for 550-16-23:
Table of Contents

Advertisement

10. Lubrication

42
1
Regulation and inspection
The oil level must not fall below the "Minimum" mark.
Caution: danger of injury
Turn off the main switch.
Work on the lubrication system may only be carried out with the
machine switched off.
Oil can cause skin eruptions.
Avoid protracted contact with the skin.
In the event of contact, thoroughly wash the affected area.
Caution:
The handling and disposal of mineral oils is subject to legal regulation.
Deliver used oil to an authorised collection point.
Protect your environment.
Take care not to spill oil.
Adjustment
Top up the oil reservoir 1 to the "maximum" mark.
The oil reservoir must only be topped up with ESSO-SP-NK 10
lubricating oil or an equivalent oil of the following specification:
viscosity at 40° C :
flashpoint:
150°C
ESSO SP-NK 10 is available from
DÜRKOPP ADLER AGretail outlets under the following part numbers:
2-litre container:
5-litre container:
10 mm²/s
9047 000013
9047 000014