6.1 Height of the Transport Foot
1
2
3
4
12
13
14
If the pressure foot 3 lies on the needle plate then the clearance
between the block 2 and the underside of the pressure foot holder 1 is
0.2 mm.
When the feed dogs are in the highest position then the transport foot
4 must lay parallel onto the feed dog.
Caution Risk of Injury !
Turn off main switch before adjusting.
–
Set the differential bottom feed according to chapter 3.2.
–
Screw out pressurescrews 5, 6 and 7.
All the pressure of the top feed device is released.
Screw 5 (threaded pin) is in the screw 6.
–
Check the pressure foot holder 1 for ease of movement.
–
Set the glide guide 13, and thus the transport foot 4, tight by
tightening the screw 14.
Check ease of movement after loosening bracket 12.
–
Lower the feed dogs by turning the handwheel.
–
Loosen screw 10.
–
By sliding the presser bar 8 set a clearance of 0.2 mm between the
pressure foot holder 1 and block 2.
–
Seat guide block 9 on the support angle 11.
–
Align the transportfoot 4 centered to the pressure foot 3.
–
Tighten screw 10.
–
The setting of the pressure screws 5, 6 and 7 is described in
chapter 6.2.
5
6
7
8
9
10
11
27