EPSON LX-300+
Figure4-14. Hook at the PG Adjust Lever
7. Remove the carriage unit along with the CR guide shaft and PG adjust
lever from the printer mechanism.
When the carriage unit is replaced, perform Bi-D adjustment.
Disassembly and Assembly
PG Adjust Lever -- Hook
Disassembly and Assembly
4.2.7.4 Ribbon Feed Mechanism Removal
1. Remove the printer mechanism. (See 4.2.3 "Printer Mechanism
Removal".)
2. Remove the tension spring, 8.10 from the motor bracket and release the
tension of the timing belt. (See 4.2.7.1 "CR Motor Assembly Removal".)
3. Release 3 hooks securing the RD cover to the left frame.
4. Remove the RD cover.
RD cover
RD ratchet
Combination gear, 51, 16.2
Left frame
Base frame
Figure4-15. Ribbon Feed Mechanism Removal
Revision A
Planetary lever assy.
Timing belt
Timing belt
Driven pulley assy.
Gear, 13.2
Combination gear, 51, 16.2
76