BUSY signal is active (HIGH level) under the conditions below:
In the process of receiving data
In the condition of being input buffer full
In the condition of being -INT signal active (low level)
During hardware initialization
In the condition of being -ERROR or PE signal is active (low level, high
level, respectively)
In the self test mode
In the adjustment mode
In the default-setting mode
-ERROR signal is active (low level) under the conditions below:
In the condition of a paper-out error
In the condition of a release lever error
PE signal is active (high level) under the condition below:
In the condition of a paper-out error
Table 1-12. Connector Pin Assignment and Signals
Return
Pin
Signal
GND
In/Out
No.
Name
Pin
1
-STROBE
19
In
2
DATA1
20
In
3
DATA2
21
In
4
DATA3
22
In
5
DATA4
23
In
6
DATA5
24
In
7
DATA6
25
In
Product Description
Functional Description
Strobe pulse. Input data is latched at
falling edge of the signal.
Parallel input data to the printer.
bit0:LSB
bit1
bit2
bit3
bit4
bit5
Interface Specifications
Table 1-12. Connector Pin Assignment and Signals
Return
Pin
Signal
GND
In/Out
No.
Name
Pin
8
DATA7
26
In
9
DATA8
27
In
10
-ACKNLG
28
Out
11
BUSY
29
Out
12
PE
28
Out
13
SLCT
28
Out
14
-AFXT
30
In
31
-INIT
30
In
32
-ERROR
29
Out
36
-SLIN
30
In
18
Logic H
--
Out
35
+5V
--
Out
17
Chassis
--
--
16, 33,
GND
--
--
19-30
15, 34
NC
--
--
NOTE: In/Out shows the direction of signal flow from the printer's
point of view.
Revision A
Functional Description
bit6
bit7:MSB
This signal (negative pulse) indicates
that the printer has received data and is
ready to accept next one.
This signal's high level means that the
print is not ready to accept data.
This signal's high level means that the
printer is in a state of paper-out error.
Always at high level when the printer is
powered on.
Not used.
This signal's negative pulse initializes
printer.
This signal's low level means the printer
is in a state of error.
Not used.
This line is pulled up to +5V through
3.9 kΩ resister.
This line is pulled up tp +5V through
1.0 kΩ resister.
Chassis GND.
Signal GND.
Not connected.