2.15.7

Folder monitoring

66
S 8
S 7
The folder in use is monitored by the sensors S 7 and S 8. The sensors
are actuated by a hexagonal bolt screwed in the pick-up folder.
If a sewing program with incorrect clamp position settings is started,
the following message appears:
Info 9014
Correction
Step back on the left pedal.
The error message is cancelled.
Select another program or alter the setting in the program.
Setting
Single piping, left
The upper sensor S 8 is active. The outer position of the left clamp
must be set.
Single piping, right
The lower sensor S 7 is active. The outer position of the right clamp
must be set.
Double piping
None of the sensors is active.